BAY-STACK-ARP-INSPECTION-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
5
.1.3.6.1.4.1.45.5.18.1.1 · 1 row entry · 3 columns
Uses the nortel variant from /opt/observium/mibs/nortel.
Command help
Walk bsArpInspectionVlanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BAY-STACK-ARP-INSPECTION-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BAY-STACK-ARP-INSPECTION-MIB::bsArpInspectionVlanTable'
This table is used to control ARP inspection settings per-VLAN.
bsArpInspectionVlanEntry row .1.3.6.1.4.1.45.5.18.1.1.1
An entry containing objects for controlling ARP inspection settings
for a VLAN.
Column Syntax OID
The VLAN ID value of the VLAN.
Q-BRIDGE-MIBVlanIndex .1.3.6.1.4.1.45.5.18.1.1.1.1
This object is used to control whether ARP inspection is enabled
for this VLAN.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.45.5.18.1.1.1.2
Indicates how arp inspection was enabled.
Supported values:
config - set by user
radius - set by radius atribute
Bits
Enumerated Values:
0config
1radius
.1.3.6.1.4.1.45.5.18.1.1.1.3
.1.3.6.1.4.1.45.5.18.1.2 · 1 row entry · 2 columns
Uses the nortel variant from /opt/observium/mibs/nortel.
Command help
Walk bsArpInspectionIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BAY-STACK-ARP-INSPECTION-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BAY-STACK-ARP-INSPECTION-MIB::bsArpInspectionIfTable'
This table is used to control ARP inspection settings per-interface.
bsArpInspectionIfEntry row .1.3.6.1.4.1.45.5.18.1.2.1
An entry containing objects for controlling ARP inspection settings
for an interface.
Column Syntax OID
The ifIndex value of the interface.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.45.5.18.1.2.1.1
This object is used to control whether this interface is trusted
for ARP inspection purposes.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.45.5.18.1.2.1.2