ATEN-PE2-CFG Table View
Table-centric layout grouping table, row, and column objects.
Tables
38
Rows
38
Columns
162
staStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.1.2
·
1 row entry
·
10 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk staStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::staStatusTable'
Station status table.
Single entry containing station status info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Station ID.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.1 |
||||||||
|
Station FW version.
If the station is not available, it returns 'station N/A'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.3.1.2.1.2 |
||||||||
|
Station model name.
If the station is not available, it returns 'station N/A' |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.3.1.2.1.3 |
||||||||
|
Outlets of the station are switchable or not.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.4 |
||||||||
|
Outlets of the station are per-port reading or not.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.5 |
||||||||
|
Station bank count.
If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.6 |
||||||||
|
Station outlet count.
If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.7 |
||||||||
|
Station sensor count.
If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.8 |
||||||||
|
The station supports auto-ping or not.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.9 |
||||||||
|
Station inlet count.
If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.10 |
staControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.1.3
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk staControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::staControlTable'
Station control table.
Single entry containing station control info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Reboot the station.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.3.1.1 |
rackConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.1.4
·
1 row entry
·
3 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk rackConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::rackConfigTable'
Rack config table.
Single entry containing rack config info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Display or set station's rack name.
string length: 1~32 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.3.1.4.1.1 |
|
Display or set station's rack row number.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-26 |
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.2 |
|
Display or set station's rack column number.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-26 |
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.3 |
devStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.1
·
1 row entry
·
4 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk devStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::devStatusTable'
Device status table.
Single entry containing device status info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Device input Current value. unit:(0.1mA)
If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.1 |
|
Device input Voltage value. unit:(0.1mV)
If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.2 |
|
Device power Capacity value. unit:(0.1mVA)
If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.3 |
|
Device circuit wired type
Example: 1 for 1 phase, 2 for 3 phase wye, 3 for 3 phase delta If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.4 |
devConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.2
·
1 row entry
·
10 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk devConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::devConfigTable'
Device config table.
Single entry containing device config info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
The name of the device.
string length: 1~39 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.1 |
||||||||
|
Display or set whether power on schedule or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.2 |
||||||||
|
This function is used to enable or disable all outlet ports to sequential reboot.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.3 |
||||||||
|
Display or set device minimum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320. NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.4 |
||||||||
|
Display or set device maximum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.5 |
||||||||
|
Display or set device minimum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.6 |
||||||||
|
Display or set device maximum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.7 |
||||||||
|
Display or set device minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not … |
Integer32r/w Constraints: range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.8 |
||||||||
|
Display or set device maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not … |
Integer32r/w Constraints: range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.9 |
||||||||
|
Display or set device maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the sta… |
Integer32r/w Constraints: range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.10 |
devControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.3
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk devControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::devControlTable'
Device control table.
Single entry containing device control info.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This function is used for outlet control of device.
Set off(1) to turn off for outlet control of device. Set on(2) to turn on for all outlet control of device. Set reboot(3) to reboot for outlet control of device. Get t… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.3.1.1 |
devReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.4
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk devReadingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::devReadingTable'
Device reading table.
Single entry containing device reading info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Device electric current value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.1 |
|
Device voltage value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.2 |
|
Device power value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.3 |
|
Device power dissipation value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.4 |
|
Device power factor value.
This value indicates that 100 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.5 |
popConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.5
·
1 row entry
·
4 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk popConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::popConfigTable'
POP config table.
Single entry containing POP config info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Display or set whether outlet POP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.1 |
||||||||
|
Display or set whether LIFO POP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.2 |
||||||||
|
Display or set whether priority POP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.3 |
||||||||
|
Indicate Outlets' power OFF priorities under Priority POP mode.
Outlet Separator ',' Bank Separator '#' Assign each priority in each bank by Outlet index or zero (indicate N/A) with separators in ascendant order. e.g. f… |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.4 |
capConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.6
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk capConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::capConfigTable'
CAP config table.
Single entry containing CAP config info.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Display or set whether CAP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.6.1.1 |
capPriorityConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.7
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk capPriorityConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::capPriorityConfigTable'
CAP priority config table.
Single entry containing CAP priority config info.
| Column | Syntax | OID |
|---|---|---|
|
Display or set the CAP Priority of outlet.
Priority 0 means this outlet does not support this OID. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 0-99 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.7.1.1 |
bankStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.1
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::bankStatusTable'
Bank status table.
Single entry containing bank status info.
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Bank ID.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.1 |
||||||||||||||||
|
The Bank Max Current value. unit: (0.1mA).
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.2 |
||||||||||||||||
|
The bank attached status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.3 |
||||||||||||||||
|
The breaker status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.4 |
||||||||||||||||
|
Display the phase layout of bank.
Example: range 1 ~ 3 represents Line1-LineNeutral ~ Line3-lineNeutral. 4 ~ 6 represents Line1-Line2, Line2-Line3, Line3-Line1. If the station does not support this OID, it retur… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.5 |
bankConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.2
·
1 row entry
·
8 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::bankConfigTable'
Bank config table.
Single entry containing bank config info.
| Column | Syntax | OID |
|---|---|---|
|
Display or set the name of the bank.
When this model does not support the OID, we show n/a. string length: 0~15 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this object … |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.1 |
|
Display or set the bank minimum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station d… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.2 |
|
Display or set the bank maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station d… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.3 |
|
Display or set the bank minimum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.4 |
|
Display or set the bank maximum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.5 |
|
Display or set the bank minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.6 |
|
Display or set the bank maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.7 |
|
Display or set the bank maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the st… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.8 |
bankControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.3
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::bankControlTable'
Bank control table.
Single entry containing bank control info.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This function is used for outlet control of bank.
Set off(1) to turn off for outlet control of bank. Set on(2) to turn on for all outlet control of bank. Set reboot(3) to reboot for outlet control of bank. Get this obje… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.3.1.1 |
bankReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.4
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk bankReadingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::bankReadingTable'
Bank reading table.
Single entry containing bank reading info.
| Column | Syntax | OID |
|---|---|---|
|
Bank electric current value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the sta… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.1 |
|
Bank voltage value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station is n… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.2 |
|
Bank power value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station is not… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.3 |
|
Bank power dissipation value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the st… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.4 |
|
Bank power Factor value.
This value indicates that 100 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.5 |
outletStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.1
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::outletStatusTable'
Outlet status table.
Single entry containing outlet status info.
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Outlet ID.
|
Integer32 Constraints: range: 1-42 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.1 |
||||||||||||||||
|
Outlet Max Current value. unit: (0.1mA).
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.2 |
||||||||||||||||
|
Outlet switchable.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.3 |
||||||||||||||||
|
Outlet latest auto-ping result.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.4 |
||||||||||||||||
|
Display the phase layout of outlet.
Example: range 1 ~ 3 represents Line1-LineNeutral ~ Line3-lineNeutral. 4 ~ 6 represents Line1-Line2, Line2-Line3, Line3-Line1. If the station does not support this OID, it retur… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.5 |
outletConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.2
·
1 row entry
·
21 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::outletConfigTable'
Outlet config table.
Single entry containing outlet config info.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Display or set the name of the outlet.
If the station does not support this OID, we show n/a. string length: 0~48 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this ob… |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.1 |
||||||||||
|
Display or set the confirmation of the outlet.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.2 |
||||||||||
|
Display or set the ON delay time of the outlet.
When this model does not support the OID, we show value -1. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.3 |
||||||||||
|
Display or set the OFF delay time of the outlet.
When this model does not support the OID, we show value -1. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.4 |
||||||||||
|
Display or set the shutdown method of the outlet.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.5 |
||||||||||
|
Display or set the MAC address of shutdown method.
The value is hex format with length 12. If the station does not support this OID, it return '00-00-00-00-00-00'. If the station is not available, it returns '00-00-00-0… |
SNMPv2-TCMacAddressr/w Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.6 |
||||||||||
|
Display or set whether the local access of the outlet is locked by remote or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.7 |
||||||||||
|
Display or set the outlet minimum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.8 |
||||||||||
|
Display or set the outlet maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.9 |
||||||||||
|
Display or set the outlet minimum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.10 |
||||||||||
|
Display or set the outlet maximum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.11 |
||||||||||
|
Display or set the outlet minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does n… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.12 |
||||||||||
|
Display or set the outlet maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does n… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.13 |
||||||||||
|
Display or set the outlet maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.14 |
||||||||||
|
Display or set the outlet auto-ping continuously-failed time to reset outlet.
Example: range 0 ~ 5 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station is not available… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-10 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.15 |
||||||||||
|
Display or set the outlet auto-ping pinging interval in seconds.
Example: range 10 ~ 600 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station is not available, it retur… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-60 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.16 |
||||||||||
|
Display or set the outlet auto-ping max retry times.
Example: range 0 ~ 5 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -30000… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-10 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.17 |
||||||||||
|
Display or set the outlet auto-ping first-ping-delay in seconds after outlet switches on.
Example: range 10 ~ 600 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station i… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-60 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.18 |
||||||||||
|
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.19 |
||||||||||
|
Display or set the outlet auto-ping enable state.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.20 |
||||||||||
|
Display or set the outlet auto-ping reboot enable state.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.21 |
outletControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.3
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::outletControlTable'
Outlet control table.
Single entry containing outlet control info.
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This function is used for the outlet control.
Set off(1) to turn off the outlet. Set on(2) to turn on the outlet. Set reboot(3) to reboot the outlet. pending(3), fault(5), noauth(6), not-suport(7), pop(8) can't be set. … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.3.1.1 |
outletReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.4
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletReadingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::outletReadingTable'
Outlet reading table.
Single entry containing outlet reading info.
| Column | Syntax | OID |
|---|---|---|
|
Outlet electric current value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.1 |
|
Outlet voltage value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.2 |
|
Outlet power value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.3 |
|
Outlet power dissipation value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.4 |
|
Outlet Power Factor value.
This value indicates that 100 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.5 |
outletAutoPingIpTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.5
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk outletAutoPingIpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::outletAutoPingIpTable'
Outlet auto-ping table.
Single entry containing outlet auto-ping ip info.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Represents the type of the corresponding instance
of outletConfigAutoPingRemoteIP object. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.5.1.1 |
||||
|
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
INET-ADDRESS-MIBInetAddressr/w Type Constraints: range: 0..255 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.5.1.2 |
lineStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.1
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk lineStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::lineStatusTable'
Line status table.
Single entry containing line status info.
| Column | Syntax | OID |
|---|---|---|
|
Line ID.
|
Integer32 Constraints: range: 1-3 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.1.1.1 |
|
The Max Line Current value. unit: (0.1mA)
If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.1.1.2 |
lineConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.2
·
1 row entry
·
6 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk lineConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::lineConfigTable'
Line config table.
Single entry containing line config info.
| Column | Syntax | OID |
|---|---|---|
|
Display or set the line Minimum current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not s… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.1 |
|
Display or set the line Maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station d… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.2 |
|
Display or set the line minimum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.3 |
|
Display or set the line maximum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.4 |
|
Display or set the line minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.5 |
|
Display or set the line maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.6 |
lineReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.3
·
1 row entry
·
3 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk lineReadingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::lineReadingTable'
Line reading table.
Single entry containing line reading info.
| Column | Syntax | OID |
|---|---|---|
|
Line current value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.1 |
|
Line voltage value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.2 |
|
Line power value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.3 |
neutralStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.4
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk neutralStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::neutralStatusTable'
Line reading table.
Single entry containing line reading info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Neutral leakage current status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.4.4.1.1 |
inletStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.5.1
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk inletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::inletStatusTable'
Inlet status table.
Single entry containing inlet status info.
| Column | Syntax | OID |
|---|---|---|
|
Line ID.
|
Integer32 Constraints: range: 1-3 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.1.1.1 |
|
The Inlet Max Current value. unit: (0.1mA).
If device is phase wye, then means L1 or L2 or L3 current. If device is phase delta, then means L1L2 or L2L3 or L3L1 current. If the station does not support this OID, it retu… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.1.1.2 |
inletConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.5.2
·
1 row entry
·
7 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk inletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::inletConfigTable'
Inlet config table.
Single entry containing inlet config info.
| Column | Syntax | OID |
|---|---|---|
|
Display or set the inlet Minimum current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.1 |
|
Display or set the inlet Maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.2 |
|
Display or set the inlet minimum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.3 |
|
Display or set the inlet maximum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.4 |
|
Display or set the inlet minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does no… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.5 |
|
Display or set the inlet maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does no… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.6 |
|
Display or set the inlet maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the s… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.7 |
inletReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.5.3
·
1 row entry
·
4 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk inletReadingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::inletReadingTable'
Inlet reading table.
Single entry containing inlet reading info.
| Column | Syntax | OID |
|---|---|---|
|
Inlet current value.
If device is phase wye, then means L1 or L2 or L3 current. If device is phase delta, then means L1L2 or L2L3 or L3L1 current. This value indicates that 10,000 times. If the station does not support … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.1 |
|
Inlet voltage value.
If device is phase wye, then means L1 or L2 or L3 voltage. If device is phase delta, then means L1L2 or L2L3 or L3L1 voltage. This value indicates that 10,000 times. If the station does not support … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.2 |
|
Inlet power value.
If device is phase wye, then means L1 or L2 or L3 power. If device is phase delta, then means L1L2 or L2L3 or L3L1 power. This value indicates that 10,000 times. If the station does not support this O… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.3 |
|
Inlet power value.
If device is phase wye, then means L1 or L2 or L3 power dissipation. If device is phase delta, then means L1L2 or L2L3 or L3L1 power dissipation. This value indicates that 10,000 times. If the station… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.4 |
sensorConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.1.3
·
1 row entry
·
8 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk sensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::sensorConfigTable'
Sensor config table. Use port/addr as indexes to access sensor configurations.
Single entry containing sensor config info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Sensor Port Number.
|
Integer32 Constraints: range: 1-4 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.1 |
|
Sensor Address.
|
Integer32 Constraints: range: 1-31 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.2 |
|
Display or set sensor minimum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -3000--3000range: -200-600 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.3 |
|
Display or set sensor maximum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -3000--3000range: -200-600 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.4 |
|
Display or set sensor minimum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 100-950 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.5 |
|
Display or set sensor maximum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 100-950 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.6 |
|
Display or set sensor minimum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station … |
Integer32r/w Constraints: range: -3000--3000range: -2500-2500 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.7 |
|
Display or set sensor maximum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station … |
Integer32r/w Constraints: range: -3000--3000range: -2500-2500 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.8 |
sensorReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.1.4
·
1 row entry
·
3 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk sensorReadingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::sensorReadingTable'
Sensor reading table. Use port/addr as indexes to access sensor readings.
Single entry containing sensor reading info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Sensor's Temperature value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the stati… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.1 |
|
Sensor's Humidity value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.2 |
|
Sensor's Pressure value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.3 |
dryContactStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.2.1
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk dryContactStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::dryContactStatusTable'
Dry contact status table.
Single entry containing dry contact status info.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Dry contact ID.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.3.2.1.1.1 |
||||||||||
|
Display dry contact status.
close(0) represents door close. open(1) represents door open. not-attached(2) represents door sensor don't attach to device. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.3.2.1.1.2 |
dryContactConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.2.2
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk dryContactConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::dryContactConfigTable'
Dry contact config table.
Single entry containing dry contact config info.
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Display or set dry contact type.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.3.2.2.1.1 |
netStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.4.1
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk netStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::netStatusTable'
Net status table.
Single entry containing net status info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Station MAC address.
The value is hex format with length 12. If the station does not support this OID, it return '00-00-00-00-00-00'. If the station is not available, it returns '00-00-00-00-00-00'. |
SNMPv2-TCMacAddress Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… |
.1.3.6.1.4.1.21317.1.3.2.3.4.1.1.1 |
httpConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.4.2
·
1 row entry
·
3 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk httpConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::httpConfigTable'
HTTP config table.
Single entry containing HTTP config info.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Display or set the HTTP port of the station.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.1 |
||||||
|
Display or set the HTTPs port of the station.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.2 |
||||||
|
Display or set whether to use HTTPS only or HTTP/HTTPS for the web page.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.3 |
netConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.4.3
·
1 row entry
·
8 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk netConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::netConfigTable'
Net config table.
Single entry containing net config info.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Network Port Number.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.1 |
||||
|
Display or set IPv4 address automatically or not
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.2 |
||||
|
Display or set fixed IPv4 address
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.3 |
||||
|
Display or set subnet mask address
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.4 |
||||
|
Display or set gateway address
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.5 |
||||
|
Display or set DNS address automatically or not
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.6 |
||||
|
Display or set prefer DNS address
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.7 |
||||
|
Display or set alternate DNS address
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.8 |
trapConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.5.1.1
·
1 row entry
·
2 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk trapConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::trapConfigTable'
Trap config table.
Single entry containing trap config info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Display or set whether this trap entry is enabled or not.
You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. If the … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.5.1.1.1.1 |
||||||||
|
Display or set SNMP trap version for sending trap.
You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. If the station… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.5.1.1.1.2 |
trapReceiverConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.5.1.2
·
1 row entry
·
7 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk trapReceiverConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::trapReceiverConfigTable'
SNMP agent trap setup table. If users want to use trap, they must set enable trap, IP and community first.
Single entry containing trap receiver config info.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of trap receiver.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.1 |
|
Trap receiver IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.2 |
|
NMS trap port to be used by agent to send trap.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.3 |
|
If use SNMPv1/v2c to receive trap should set this community string.
MAX string length: 20 If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station N/… |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.4 |
|
If use SNMPv3 to receive trap should set this username string.
MAX string length: 20. If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station N/A'. … |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.5 |
|
If use SNMPv3 to receive trap should set this auth password string.
MAX string length: 20 If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station N/… |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.6 |
|
If use SNMPv3 to receive trap should set this privacy password string.
MAX string length: 20 If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station… |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.7 |
trapReceiverIpTable
table.1.3.6.1.4.1.21317.1.3.2.3.5.1.3
·
1 row entry
·
3 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk trapReceiverIpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::trapReceiverIpTable'
Trap Receiver Ip table.
Single entry containing trap receiver ip info.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index of trap receiver.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.1 |
||||
|
Represents the type of the corresponding instance
of trapReceiverIp object. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.2 |
||||
|
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
INET-ADDRESS-MIBInetAddressr/w Type Constraints: range: 0..255 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.3 |
trapNotifConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.50.1
·
1 row entry
·
1 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk trapNotifConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::trapNotifConfigTable'
Trap notification config table.
Single entry containing trap notification config info.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Display or set whether this trap entry is enabled or not.
You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. If the … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.1.1.1 |
trapNotifAlarmTable
table.1.3.6.1.4.1.21317.1.3.2.3.50.2
·
1 row entry
·
5 columns
Uses the aten variant from
Command help
/opt/observium/mibs/aten.
Walk trapNotifAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATEN-PE2-CFG' -M '/opt/observium/mibs/aten:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATEN-PE2-CFG::trapNotifAlarmTable'
Trap notification alarm table.
Single entry containing trap notification alarm info.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Station breaker alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.1 |
||||||
|
Station current alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.2 |
||||||
|
Station voltage alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.3 |
||||||
|
Station power alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.4 |
||||||
|
Station sensor alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.5 |