.1.3.6.1.4.1.207.8.4.4.3.28.1.1 · 1 row entry · 9 columns
Uses the allied variant from /opt/observium/mibs/allied.
Command help
Walk atPluggableDiagTempTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AT-PLUGGABLE-DIAGNOSTICS-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AT-PLUGGABLE-DIAGNOSTICS-MIB::atPluggableDiagTempTable'
A table of information regarding the various temperature parameters observed
as a part of Digital diagnostics monitoring, for all the optical pluggables
installed in the devices.
atPluggableDiagTempEntry row .1.3.6.1.4.1.207.8.4.4.3.28.1.1.1
The information about various temperature parameters of pluggables
such as current status reading, current alarm status, higher and lower
alarm threshold, current warning, higher and lower warning threshold.
Column Syntax OID
The ifindex of the pluggable.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.1
The channel number of the pluggable.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.2
The current temperature status reading.
0.001 degree CSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.3
The current temperature alarm reading.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.4
The maximum temperature alarm threshold value.
0.001 degree CSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.5
The minimum temperature alarm threshold value.
0.001 degree CSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.6
The current temperature warnings.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.7
The maximum temperature warning threshold value.
0.001 degree CSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.8
The minimum temperature warning threshold value.
0.001 degree CSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.9
.1.3.6.1.4.1.207.8.4.4.3.28.1.2 · 1 row entry · 9 columns
Uses the allied variant from /opt/observium/mibs/allied.
Command help
Walk atPluggableDiagVccTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AT-PLUGGABLE-DIAGNOSTICS-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AT-PLUGGABLE-DIAGNOSTICS-MIB::atPluggableDiagVccTable'
A table of information regarding the various Voltage (Vcc) parameters observed
as a part of Digital diagnostics monitoring, for all the optical pluggables
installed in the devices.
atPluggableDiagVccEntry row .1.3.6.1.4.1.207.8.4.4.3.28.1.2.1
The information about various Voltage (Vcc) parameters of pluggables
such as current status reading, current alarm status, higher and lower
alarm threshold, current warning, higher and lower warning threshold.
Column Syntax OID
The ifindex of the pluggable.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.1
The channel number of the pluggable.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.2
The current Voltage (Vcc) status reading.
0.0001 voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.3
The current Voltage (Vcc) alarm reading.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.4
The maximum Voltage (Vcc) alarm threshold value.
0.0001 voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.5
The minimum Voltage (Vcc) alarm threshold value.
0.0001 voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.6
The current Voltage (Vcc) warnings.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.7
The maximum Voltage (Vcc) warning threshold value.
0.0001 voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.8
The minimum Voltage (Vcc) warning threshold value.
0.0001 voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.9
.1.3.6.1.4.1.207.8.4.4.3.28.1.3 · 1 row entry · 9 columns
Uses the allied variant from /opt/observium/mibs/allied.
Command help
Walk atPluggableDiagTxBiasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AT-PLUGGABLE-DIAGNOSTICS-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AT-PLUGGABLE-DIAGNOSTICS-MIB::atPluggableDiagTxBiasTable'
A table of information regarding the various Tx Bias Current (mA)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices.
atPluggableDiagTxBiasEntry row .1.3.6.1.4.1.207.8.4.4.3.28.1.3.1
The information about various Tx Bias Current (mA)
parameters of pluggables such as current status reading,
current alarm status, higher and lower alarm threshold,
current warning, higher and lower warning threshold.
Column Syntax OID
The ifindex of the pluggable.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.1
The channel number of the pluggable.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.2
The current Tx Bias (mA) status reading.
0.001 mASNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.3
The current Tx Bias (mA) alarm reading.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.4
The maximum Tx Bias (mA) alarm threshold value.
0.001 mASNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.5
The minimum Tx Bias (mA) alarm threshold value.
0.001 mASNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.6
The current Tx Bias (mA) warnings.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.7
The maximum Tx Bias (mA) warning threshold value.
0.001 mASNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.8
The minimum Tx Bias (mA) warning threshold value.
0.001 mASNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.9
.1.3.6.1.4.1.207.8.4.4.3.28.1.4 · 1 row entry · 9 columns
Uses the allied variant from /opt/observium/mibs/allied.
Command help
Walk atPluggableDiagTxPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AT-PLUGGABLE-DIAGNOSTICS-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AT-PLUGGABLE-DIAGNOSTICS-MIB::atPluggableDiagTxPowerTable'
A table of information regarding the various Tx Power (mW)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices.
atPluggableDiagTxPowerEntry row .1.3.6.1.4.1.207.8.4.4.3.28.1.4.1
The information about various Tx Power (mW)
parameters of pluggables such as current status reading,
current alarm status, higher and lower alarm threshold,
current warning, higher and lower warning threshold.
Column Syntax OID
The ifindex of the pluggable.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.1
The channel number of the pluggable.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2
The current Tx Power (mW) status reading.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3
The current Tx Power (mW) alarm reading.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.4
The maximum Tx Power (mW) alarm threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.5
The minimum Tx Power (mW) alarm threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.6
The current Tx Power (mW) warnings.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.7
The maximum Tx Power (mW) warning threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.8
The minimum Tx Power (mW) warning threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.9
.1.3.6.1.4.1.207.8.4.4.3.28.1.5 · 1 row entry · 9 columns
Uses the allied variant from /opt/observium/mibs/allied.
Command help
Walk atPluggableDiagRxPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AT-PLUGGABLE-DIAGNOSTICS-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AT-PLUGGABLE-DIAGNOSTICS-MIB::atPluggableDiagRxPowerTable'
A table of information regarding the various Rx Power (mW)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices.
atPluggableDiagRxPowerEntry row .1.3.6.1.4.1.207.8.4.4.3.28.1.5.1
The information about various Rx Power (mW)
parameters of pluggables such as current status reading,
current alarm status, higher and lower alarm threshold,
current warning, higher and lower warning threshold.
Column Syntax OID
The ifindex of the pluggable.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.1
The channel number of the pluggable.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.2
The current Rx Power (mW) status reading.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3
The current Rx Power (mW) alarm reading.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.4
The maximum Rx Power (mW) alarm threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.5
The minimum Rx Power (mW) alarm threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.6
The current Rx Power (mW) warnings.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.7
The maximum Rx Power (mW) warning threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.8
The minimum Rx Power (mW) warning threshold value.
0.0001 mWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.9
.1.3.6.1.4.1.207.8.4.4.3.28.1.6 · 1 row entry · 3 columns
Uses the allied variant from /opt/observium/mibs/allied.
Command help
Walk atPluggableDiagRxLosTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AT-PLUGGABLE-DIAGNOSTICS-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AT-PLUGGABLE-DIAGNOSTICS-MIB::atPluggableDiagRxLosTable'
A table of information regarding the Rx Loss of Singal (Los)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices.
atPluggableDiagRxLosEntry row .1.3.6.1.4.1.207.8.4.4.3.28.1.6.1
The information about various Rx Loss of Singal (Los) parameters
of pluggables such as current status reading.
Column Syntax OID
The ifindex of the pluggable.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.1
The channel number of the pluggable.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.2
The current Rx Los status reading.
OctetString .1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.3