The AT Environment Monitoring v2 MIB for managing and
reporting data relating to voltage rails, fan speeds,
temperature sensors and power supply units.
A notification generated when the monitored speed of a fan
drops below its lower threshold.
atEnvMonv2ContactInputCloseNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.10
A notification generated when a monitored contact input closes.
atEnvMonv2ExternalPSUAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.11
A notification generated when supply potential of
a monitored external power supply is not present.
atEnvMonv2ExternalPSUAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.12
A notification generated when supply potential of
a monitored external power supply returns to an
acceptable value, having previously been in an
alarm condition.
atEnvMonv2TempCriticalSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.13
A notification generated when a monitored temperature
exceeds its upper threshold.
atEnvMonv2TempCriticalClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.14
A notification generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition.
atEnvMonv2TempCriticalLevel1SetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.15
A notification generated when a monitored temperature
exceeds the level 1 threshold.
atEnvMonv2TempCriticalLevel1ClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.16
A notification generated when a monitored temperature
returns to an acceptable value, having previously been in
critical temperature level 1 condition.
atEnvMonv2TempCriticalLevel2SetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.17
A notification generated when a monitored temperature
exceeds the level 2 threshold.
atEnvMonv2TempCriticalLevel2ClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.18
A notification generated when a monitored temperature
returns to an acceptable value, having previously been in
critical temperature level 2 condition.
atEnvMonv2PsbPresenceChangeNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.19
A notification generated when an insertion or removal
event is detected on a power supply bay device.
atEnvMonv2FanAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.2
A notification generated when the monitored speed of a fan
returns to an acceptable value, the fan
having previously been in an alarm condition.
atEnvMonv2VoltAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.3
A notification generated when the voltage of a monitored
voltage rail goes out of tolerance, either by
dropping below its lower threshold, or exceeding
its upper threshold.
atEnvMonv2VoltAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.4
A notification generated when the voltage of a monitored
voltage rail returns to an acceptable value,
having previously been in an alarm condition.
atEnvMonv2TempAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.5
A notification generated when a monitored temperature
exceeds its upper threshold.
atEnvMonv2TempAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.6
A notification generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition.
atEnvMonv2PsbAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.7
A notification generated when a monitored parameter of
a power supply bay device goes out of
tolerance.
atEnvMonv2PsbAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.8
A notification generated when a monitored parameter of
a power supply bay device returns to an
acceptable value, having previously been
in an alarm condition.
atEnvMonv2ContactInputOpenNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.9
A notification generated when a monitored contact input opens.
atEnvMonv2FanAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.1
A trap generated when the monitored speed of a fan
drops below its lower threshold.
atEnvMonv2FanAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.2
A trap generated when the monitored speed of a fan
returns to an acceptable value, the fan
having previously been in an alarm condition.
atEnvMonv2VoltAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.3
A trap generated when the voltage of a monitored
voltage rail goes out of tolerance, either by
dropping below its lower threshold, or exceeding
its upper threshold.
atEnvMonv2VoltAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.4
A trap generated when the voltage of a monitored
voltage rail returns to an acceptable value,
having previously been in an alarm condition.
atEnvMonv2TempAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.5
A trap generated when a monitored temperature
exceeds its upper threshold.
atEnvMonv2TempAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.6
A trap generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition.
atEnvMonv2PsbAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.7
A trap generated when a monitored parameter of
a power supply bay device goes out of
tolerance.
atEnvMonv2PsbAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.8
A trap generated when a monitored parameter of
a power supply bay device returns to an
acceptable value, having previously been
in an alarm condition.