The AT Environment Monitoring v2 MIB for managing and
reporting data relating to voltage rails, fan speeds,
temperature sensors and power supply units.
tion generated when the monitored speed of a fan
drops below its lower threshold.
atEnvMonv2ContactInputCloseNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.10
A notification generated when a monitored contact input closes.
atEnvMonv2ExternalPSUAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.11
tion generated when supply potential of
a monitored external power supply is not present.
atEnvMonv2ExternalPSUAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.12
tion generated when supply potential of
a monitored external power supply returns to an
acceptable value, having previously been in an
alarm condition.
atEnvMonv2TempCriticalSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.13
tion generated when a monitored temperature
exceeds its upper threshold.
atEnvMonv2TempCriticalClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.14
tion generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition.
atEnvMonv2TempCriticalLevel1SetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.15
tion generated when a monitored temperature
exceeds the level 1 threshold.
atEnvMonv2TempCriticalLevel1ClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.16
tion generated when a monitored temperature
returns to an acceptable value, having previously been in
critical temperature level 1 condition.
atEnvMonv2TempCriticalLevel2SetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.17
tion generated when a monitored temperature
exceeds the level 2 threshold.
atEnvMonv2TempCriticalLevel2ClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.18
tion generated when a monitored temperature
returns to an acceptable value, having previously been in
critical temperature level 2 condition.
atEnvMonv2PsbPresenceChangeNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.19
tion generated when an insertion or removal
event is detected on a power supply bay device.
atEnvMonv2FanAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.2
tion generated when the monitored speed of a fan
returns to an acceptable value, the fan
having previously been in an alarm condition.
atEnvMonv2VoltAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.3
tion generated when the voltage of a monitored
voltage rail goes out of tolerance, either by
dropping below its lower threshold, or exceeding
its upper threshold.
atEnvMonv2VoltAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.4
tion generated when the voltage of a monitored
voltage rail returns to an acceptable value,
having previously been in an alarm condition.
atEnvMonv2TempAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.5
tion generated when a monitored temperature
exceeds its upper threshold.
atEnvMonv2TempAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.6
tion generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition.
atEnvMonv2PsbAlarmSetNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.7
tion generated when a monitored parameter of
a power supply bay device goes out of
tolerance.
atEnvMonv2PsbAlarmClearedNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.8
tion generated when a monitored parameter of
a power supply bay device returns to an
acceptable value, having previously been
in an alarm condition.
atEnvMonv2ContactInputOpenNotify
.1.3.6.1.4.1.207.8.4.4.3.12.0.9
A notification generated when a monitored contact input opens.
atEnvMonv2FanAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.1
erated when the monitored speed of a fan
drops below its lower threshold.
atEnvMonv2FanAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.2
erated when the monitored speed of a fan
returns to an acceptable value, the fan
having previously been in an alarm condition.
atEnvMonv2VoltAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.3
erated when the voltage of a monitored
voltage rail goes out of tolerance, either by
dropping below its lower threshold, or exceeding
its upper threshold.
atEnvMonv2VoltAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.4
erated when the voltage of a monitored
voltage rail returns to an acceptable value,
having previously been in an alarm condition.
atEnvMonv2TempAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.5
erated when a monitored temperature
exceeds its upper threshold.
atEnvMonv2TempAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.6
erated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition.
atEnvMonv2PsbAlarmSetEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.7
erated when a monitored parameter of
a power supply bay device goes out of
tolerance.
atEnvMonv2PsbAlarmClearedEvent
.1.3.6.1.4.1.207.8.4.4.3.12.5.8
erated when a monitored parameter of
a power supply bay device returns to an
acceptable value, having previously been
in an alarm condition.