ALCATEL-IND1-INLINE-POWER-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
12
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.1 · 1 row entry · 4 columns
Uses the alcatel variant from /opt/observium/mibs/alcatel.
Command help
Walk alaPethPsePortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALCATEL-IND1-INLINE-POWER-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALCATEL-IND1-INLINE-POWER-MIB::alaPethPsePortTable'
A table of objects that augments the standard pethPsePortTable
entry by adding the alaPethPsePortPowerMaximum object.
alaPethPsePortEntry row .1.3.6.1.4.1.6486.800.1.2.1.27.1.1.1.1
A set of objects that display and control the power
characteristics of a power Ethernet PSE port.
Indexes
No indexes recorded
Column Syntax OID
This object controls maximum amount of power per port.
Integer32r/w
Constraints:
range: 3000-75000
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.1.1.1
This object contains the actual amount of power used by a port
Integer32
Constraints:
range: 0-30000
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.1.1.2
This object contains the power status of a port
Enumeration
Enumerated Values:
1powerOn
2powerOff
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.1.1.3
This object controls class of poe device attached on a port.
class0 - The device can draw PD power from 0.44W to 12.95W and
current less than 5.0 mA.
class1 - The device can draw PD power from 0.44W to 3.84W and
Enumeration
Enumerated Values:
0class0
1class1
2class2
3class3
4class4
5class5
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.1.1.4
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2 · 1 row entry · 6 columns
Uses the alcatel variant from /opt/observium/mibs/alcatel.
Command help
Walk alaPethMainPseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALCATEL-IND1-INLINE-POWER-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALCATEL-IND1-INLINE-POWER-MIB::alaPethMainPseTable'
This table augments the standard table PethMainPseTable by allowing the 
admin status for a group to be set to on/off as well as
showing the values for the max power for that group.
alaPethMainPseEntry row .1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2.1
A set of objects that display and control the Main power
of a PSE.
Indexes
No indexes recorded
Column Syntax OID
The object is used to set the status of the main PSE to ON or OFF.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2.1.1
The maximum amount of power allowed for main PSE.
WattsInteger32r/w
Constraints:
range: 36-800
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2.1.2
The object is used to set the priority disconnect of the
main PSE to Enabled or Disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2.1.3
The object is used to enable or disable the PowerDsine
Capacitor detection method.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2.1.4
The object is set the power down priority for the slot
Enumerationr/w
Enumerated Values:
1critical
2high
3low
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2.1.5
The object is used to set the combo port option of the
main PSE to Enable or Disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.6486.800.1.2.1.27.1.1.2.1.6
.1.3.6.1.4.1.6486.800.1.2.1.27.1.3.1 · 1 row entry · 2 columns
Uses the alcatel variant from /opt/observium/mibs/alcatel.
Command help
Walk alaPethMainTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALCATEL-IND1-INLINE-POWER-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALCATEL-IND1-INLINE-POWER-MIB::alaPethMainTable'
A table of objects that augments the standard pethPsePortTable
entry by adding the alaPethPsePortPowerMaximum object.
alaPethMainEntry row .1.3.6.1.4.1.6486.800.1.2.1.27.1.3.1.1
A set of objects that display and control the power
characteristics of a power Ethernet PSE port.
Column Syntax OID
This variable uniquely identifies the group to which
power Ethernet PSE is connected.Group means (box in the stack,
module in a rack) and the value 1 MUST be used for non-modular
devices
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.6486.800.1.2.1.27.1.3.1.1.1
This object controls power supply redundancy.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.6486.800.1.2.1.27.1.3.1.1.2