ADVA-FSPR7-CFM-EXTENSION-MIB
This is a MIB definition for ADVA AG Optical Networking CFM extension objects.
- Source file
ADVA-FSPR7-CFM-EXTENSION-MIB- Last revised
- Identity
cfmExtensionMIB- Base OID
1.3.6.1.4.1.2544.1.11.6
Imported Objects
| ADVA-MIB | fspR7 neEventLogIdentityTranslation neEventLogTimeStamp ServiceImpairment TrapAlarmSeverity |
| FspR7-LAYER2-MIB | flowEntityIndexEth flowEntityIndexFlow |
| IEEE8021-CFM-MIB | dot1agCfmMaIndex dot1agCfmMdIndex dot1agCfmMepIdentifier |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | DateAndTime TEXTUAL-CONVENTION (no object page) |
Net-SNMP examples using the adva MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'ADVA-FSPR7-CFM-EXTENSION-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ADVA-FSPR7-CFM-EXTENSION-MIB::cfmExtensionMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ADVA-FSPR7-CFM-EXTENSION-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ADVA-FSPR7-CFM-EXTENSION-MIB::cfmExtensionMIB'
Objects (27)
Showing 27 of 27 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.2544.1.11.6 |
||
.1.3.6.1.4.1.2544.1.11.6.1 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.10 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.10.1 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.10.1.1 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.10.1.2 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.10.1.3 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.10.1.4 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.10.1.5 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1.1 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1.2 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1.3 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1.4 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1.5 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1.6 |
||
.1.3.6.1.4.1.2544.1.11.6.1.1.11.1.7 |
||
.1.3.6.1.4.1.2544.1.11.6.1.2 |
||
.1.3.6.1.4.1.2544.1.11.6.1.2.0 |
||
.1.3.6.1.4.1.2544.1.11.6.2 |
||
.1.3.6.1.4.1.2544.1.11.6.2.1 |
||
.1.3.6.1.4.1.2544.1.11.6.2.1.1 |
||
.1.3.6.1.4.1.2544.1.11.6.2.1.1.1 |
||
.1.3.6.1.4.1.2544.1.11.6.2.1.1.1.1 |
||
.1.3.6.1.4.1.2544.1.11.6.2.2 |
Dependencies (27) 7 direct · 20 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANA-ENTITY-MIBrfc
- SNMPv2-CONFrfc
- SNMP-FRAMEWORK-MIBrfc
- UUID-TC-MIBrfc
- ENTITY-MIBrfc
- IANAifType-MIBrfc
- SNMPv2-MIBrfc
- IF-MIBrfc
- ADVA-MIBadva
- FspR7-MIBadva
- FspR7-LAYER2-MIBadva
- IEEE8021-TC-MIBrfc
- IANA-ADDRESS-FAMILY-NUMBERS-MIBrfc
- RMON-MIBrfc
- RFC-1212rfc
- RFC1155-SMIrfc
- RFC1213-MIBrfc
- RFC1271-MIBrfc
- TOKEN-RING-RMON-MIBrfc
- RMON2-MIBrfc
- LLDP-MIBrfc
- BRIDGE-MIBrfc
- P-BRIDGE-MIBrfc
- Q-BRIDGE-MIBrfc
- IEEE8021-CFM-MIBrfc
- ADVA-FSPR7-CFM-EXTENSION-MIBadvaselected
Type Definitions (1)
| Enumeration |
undefined(0)cfmOosDisabled(13000)cfmOosManagement(13001)cfmOosMaintenance(13002)cfmOosAins(13003)cfmPriVidNotEqualExtVid(13004)cfmServerSignalFailure(13005)cfmRemoteDefectIndication(13006)cfmCcmMacStatus(13007)cfmCcmError(13008)cfmCcmLost(13009)cfmCcmXConn(13010) |
Conformance Groups (2)
|
A list of objects.
|
.1.3.6.1.4.1.2544.1.11.6.2.2.1
|
|
|
alarmCfmOosDisabled alarmCfmOosManagement alarmCfmOosMaintenance alarmCfmOosAins alarmCfmPriVidNotEqualExtVid alarmCfmServerSignalFailure alarmCfmRemoteDefectIndication alarmCfmCcmMacStatus alarmCfmCcmError alarmCfmCcmLost alarmCfmCcmXConn
A list of notifications.
|
.1.3.6.1.4.1.2544.1.11.6.2.2.2
|
Compliance Statements (1)
OID
.1.3.6.1.4.1.2544.1.11.6.2.1.1The compliance statement for entities implementing the ADVA FSPR7 CFM Extension MIB.
Required groups
| mandatory | cfmExtensionObjectGroup | |
| mandatory | cfmExtensionNotificationGroup |
Notifications / Traps (11)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13000 |
Non-Specific Disablement of Management Access
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13001 |
Alarms are logged but not notified, service affecting changes are permitted
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13002 |
Alarms are logged but not notified, service affecting changes and operations are permitted
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13003 |
Automatic In Service
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13004 |
MEP Primary VLAN ID and Flow External VLAN ID are different
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13005 |
All member ports signals have failed
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13006 |
RDI
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13007 |
MAC status of the port
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13008 |
Error in the CCM received
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13009 |
3 or more CCMs not recieved from far end MEP
|
|
.1.3.6.1.4.1.2544.1.11.6.1.2.0.13010 |
Cross connected CCM
|