ADTRAN-AOS-SFP-MIB

        The MIB module is for AdtranOS SFP Status.
    
Source file
ADTRAN-AOS-SFP-MIB
Last revised
Identity
adGenAOSSfp
Base OID
1.3.6.1.4.1.664.5.53.1.12
Imported Objects
ADTRAN-AOS adGenAOSCommon adGenAOSConformance
ADTRAN-MIB adIdentity
IF-MIB ifDescr ifIndex
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32
SNMPv2-TC DisplayString TEXTUAL-CONVENTION (no object page) TruthValue
Net-SNMP examples using the adtran MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'ADTRAN-AOS-SFP-MIB' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ADTRAN-AOS-SFP-MIB::adGenAOSSfp'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ADTRAN-AOS-SFP-MIB' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ADTRAN-AOS-SFP-MIB::adGenAOSSfp'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (9)
.1.3.6.1.4.1.664.5.53.1.12
.1.3.6.1.4.1.664.5.53.99.30
.1.3.6.1.4.1.664.5.53.99.30.1
.1.3.6.1.4.1.664.5.53.99.30.2
.1.3.6.1.4.1.664.6.10000.53.1.12
.1.3.6.1.4.1.664.6.10000.53.1.12.0
.1.3.6.1.4.1.664.6.10000.53.1.12.1
OctetString
.1.3.6.1.4.1.664.6.10000.53.1.12.2
OctetString
.1.3.6.1.4.1.664.6.10000.53.1.12.3
Dependencies (8) 6 direct · 2 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-CONFrfc
  3. SNMPv2-TCrfc
  4. ADTRAN-MIBadtran
  5. ADTRAN-AOSadtran
  6. IANAifType-MIBrfc
  7. SNMPv2-MIBrfc
  8. IF-MIBrfc
  9. ADTRAN-AOS-SFP-MIBadtranselected
Type Definitions (1)
Enumeration
alarmThresholdHigh(1)
alarmThresholdLow(2)
Conformance Groups (2)
Compliance Statements (1)

OID .1.3.6.1.4.1.664.5.53.99.30.2.1
The compliance statement for SNMP entities which implement
version 2 of the adGenAOSSfp MIB.
Required groups
Notifications / Traps (13)
NameOIDDescription
.1.3.6.1.4.1.664.6.10000.53.1.12.0.1
This trap indicates that Rx Power exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.10
This trap indicates that Bias Current is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.11
This trap indicates that SFP inserted is not supported by AdtranOS.
Information about the SFP is contained with in this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.12
This trap indicates that SFP is inserted into device.
Information about the SFP and the interface is contained in this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.13
This trap indicates that SFP is removed from device.
Information about the SFP and the interface is contained in this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.2
This trap indicates that Rx Power is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.3
This trap indicates that Tx Power exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.4
This trap indicates that Tx Power is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.5
This trap indicates that Supply voltage exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.6
This trap indicates that supply voltage is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.7
This trap indicates that Temperature exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.8
This trap indicates that Temperature is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap.
.1.3.6.1.4.1.664.6.10000.53.1.12.0.9
This trap indicates that Bias Current exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap.