adSfpAlarmRxPowerError | .1.3.6.1.4.1.664.6.10000.53.1.12.0.1 | indicates that Rx Power exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap. |
adSfpAlarmBiasCurrentResume | .1.3.6.1.4.1.664.6.10000.53.1.12.0.10 | indicates that Bias Current is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap. |
adSfpTypeFailure | .1.3.6.1.4.1.664.6.10000.53.1.12.0.11 | indicates that SFP inserted is not supported by AdtranOS.
Information about the SFP is contained with in this trap. |
adSfpEntConfigChangeInsertion | .1.3.6.1.4.1.664.6.10000.53.1.12.0.12 | indicates that SFP is inserted into device.
Information about the SFP and the interface is contained in this trap. |
adSfpEntConfigChangeRemoval | .1.3.6.1.4.1.664.6.10000.53.1.12.0.13 | indicates that SFP is removed from device.
Information about the SFP and the interface is contained in this trap. |
adSfpAlarmRxPowerResume | .1.3.6.1.4.1.664.6.10000.53.1.12.0.2 | indicates that Rx Power is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap. |
adSfpAlarmTxPowerError | .1.3.6.1.4.1.664.6.10000.53.1.12.0.3 | indicates that Tx Power exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap. |
adSfpAlarmTxPowerResume | .1.3.6.1.4.1.664.6.10000.53.1.12.0.4 | indicates that Tx Power is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap. |
adSfpAlarmSupplyVoltageError | .1.3.6.1.4.1.664.6.10000.53.1.12.0.5 | indicates that Supply voltage exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap. |
adSfpAlarmSupplyVoltageResume | .1.3.6.1.4.1.664.6.10000.53.1.12.0.6 | indicates that supply voltage is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap. |
adSfpAlarmTemperatureError | .1.3.6.1.4.1.664.6.10000.53.1.12.0.7 | indicates that Temperature exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap. |
adSfpAlarmTemperatureResume | .1.3.6.1.4.1.664.6.10000.53.1.12.0.8 | indicates that Temperature is with in the alarm thresholds
range for an SFP. Information about the SFP is contained with in
this trap. |
adSfpAlarmBiasCurrentError | .1.3.6.1.4.1.664.6.10000.53.1.12.0.9 | indicates that Bias Current exceeded alarm threshold level
for an SFP. Information about the SFP and alarm threshold type are
contained with in this trap. |