ADTRAN-AOS-POWER
The MIB module for general configuration of power
monitoring options for devices with battery backup.
- Source file
ADTRAN-AOS-POWER- Last revised
- Identity
adGenAOSPowerMonitor- Base OID
1.3.6.1.4.1.664.5.53.7.1
Imported Objects
| ADTRAN-AOS | adGenAOSConformance adGenAOSPower |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION (no object page) TruthValue |
Net-SNMP examples using the adtran MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'ADTRAN-AOS-POWER' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ADTRAN-AOS-POWER::adGenAOSPowerMonitor'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ADTRAN-AOS-POWER' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ADTRAN-AOS-POWER::adGenAOSPowerMonitor'
Objects (16)
Showing 16 of 16 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.664.5.53.7.0 |
||
.1.3.6.1.4.1.664.5.53.7.1 |
||
.1.3.6.1.4.1.664.5.53.7.1.1 |
||
.1.3.6.1.4.1.664.5.53.7.1.1.1 |
||
.1.3.6.1.4.1.664.5.53.7.1.1.2 |
||
.1.3.6.1.4.1.664.5.53.7.1.2 |
||
.1.3.6.1.4.1.664.5.53.7.1.2.1 |
||
.1.3.6.1.4.1.664.5.53.7.1.2.1.1 |
||
.1.3.6.1.4.1.664.5.53.7.1.2.1.1.1 |
||
.1.3.6.1.4.1.664.5.53.7.1.2.1.1.2 |
||
.1.3.6.1.4.1.664.5.53.7.1.2.1.1.3 |
||
.1.3.6.1.4.1.664.5.53.7.1.2.1.1.4 |
||
.1.3.6.1.4.1.664.5.53.7.1.2.1.1.5 |
||
.1.3.6.1.4.1.664.5.53.99.11 |
||
.1.3.6.1.4.1.664.5.53.99.11.1 |
||
.1.3.6.1.4.1.664.5.53.99.11.2 |
Dependencies (5) 4 direct · 1 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-CONFrfc
- SNMPv2-TCrfc
- ADTRAN-MIBadtran
- ADTRAN-AOSadtran
- ADTRAN-AOS-POWERadtranselected
Type Definitions (3)
| Enumeration |
delivering(1)notDelivering(2)failed(3)unknown(4) |
|
| Enumeration |
connected(1)notConnected(2)notApplicable(3)unknown(4) |
|
| Enumeration |
failed(1)busy(2)delivering(3)available(4)unknown(5) |
Conformance Groups (5)
|
Trap which may be used to enhance power event driven
management of the Unit. |
.1.3.6.1.4.1.664.5.53.99.11.1.1
|
|
|
The Unit SNMP Config Group.
|
.1.3.6.1.4.1.664.5.53.99.11.1.2
|
|
|
Trap used to indicate state changes of EPS.
|
.1.3.6.1.4.1.664.5.53.99.11.1.3
|
|
|
Trap used to indicate state changes of RPS.
|
.1.3.6.1.4.1.664.5.53.99.11.1.4
|
|
|
adGenAOSPowerEpsRpsInstanceId adGenAOSPowerRpsConnectionState adGenAOSPowerRpsDeliveryState adGenAOSPowerEpsConnectionState adGenAOSPowerEpsDeliveryState
The Unit SNMP Config Group.
|
.1.3.6.1.4.1.664.5.53.99.11.1.5
|
Compliance Statements (1)
OID
.1.3.6.1.4.1.664.5.53.99.11.2.1The compliance statement for SNMP entities which implement
version 2 of the adGenAOSPower MIB. When this MIB is fully
implemented, then such an implementation can claim
full compliance.
version 2 of the adGenAOSPower MIB. When this MIB is fully
implemented, then such an implementation can claim
full compliance.
Required groups
| optional | adGenAOSPowerRollOverCtlGroup |
A collection of objects providing read/write configuration information for the management of power rollovers. |
| optional | adGenAOSPowerNotificationGroup |
This mandatory group is used for the management of power rollover notifications. |
| optional | adGenAOSEpsRpsConfigurationGroup |
A collection of objects providing read-only configuration information for the management of EPS and RPS. |
| optional | adGenAOSEpsNotificationGroup |
This mandatory group is used for the management of EPS notifications. |
| optional | adGenAOSRpsNotificationGroup |
This mandatory group is used for the management of RPS notifications. |
Notifications / Traps (5)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.664.5.53.7.0.1 |
This trap indicates the unit has had a change in power source, either from AC to DC or back again. The SecSinceEpoch represents the time (seconds since epoch) that the rollover occured.
|
|
.1.3.6.1.4.1.664.5.53.7.0.2 |
This trap indicates the unit has had a change in the EPS connection state.
|
|
.1.3.6.1.4.1.664.5.53.7.0.3 |
This trap indicates the unit has had a change in the EPS delivery state.
|
|
.1.3.6.1.4.1.664.5.53.7.0.4 |
This trap indicates the unit has had a change in the RPS connection state.
|
|
.1.3.6.1.4.1.664.5.53.7.0.5 |
This trap indicates the unit has had a change in the RPS delivery state.
|