ACD-ALARM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
14
.1.3.6.1.4.1.22420.2.1.10 · 1 row entry · 9 columns
Uses the accedian variant from /opt/observium/mibs/accedian.
Command help
Walk acdAlarmCfgTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ACD-ALARM-MIB' -M '/opt/observium/mibs/accedian:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ACD-ALARM-MIB::acdAlarmCfgTable'
Table of all alarms.
acdAlarmCfgEntry row .1.3.6.1.4.1.22420.2.1.10.1
An alarm is an exceptional event that requires user notificaton.
Indexes
No indexes recorded
Column Syntax OID
Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes).
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22420.2.1.10.1.1
Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.BBB.CC and is…
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22420.2.1.10.1.2
This string is to describe the alarm in a readable way, e.g.:
+5Vdc Power supply fail.
OctetStringr/w .1.3.6.1.4.1.22420.2.1.10.1.3
This is to indicate if the alarm is reported or not.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.22420.2.1.10.1.4
Accedian Networks classifies alarms into four severity types. These types
and their associated decimal codes are, informational(0), minor(1),
major(2) and critical(3).
Enumerationr/w .1.3.6.1.4.1.22420.2.1.10.1.5
This is to indicate if the alarm is service affecting or not. This
value depends on the utilization of the box. For instance in an
application where the monitoring of the traffic is mandatory the link
down event on the …
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.22420.2.1.10.1.6
Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.B.C and is ex…
OctetString .1.3.6.1.4.1.22420.2.1.10.1.7
This is the type of alarm condition.
OctetString .1.3.6.1.4.1.22420.2.1.10.1.8
This is the Alarm Maintenance Object.
OctetString .1.3.6.1.4.1.22420.2.1.10.1.9
.1.3.6.1.4.1.22420.2.1.11 · 1 row entry · 5 columns
Uses the accedian variant from /opt/observium/mibs/accedian.
Command help
Walk acdAlarmStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ACD-ALARM-MIB' -M '/opt/observium/mibs/accedian:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ACD-ALARM-MIB::acdAlarmStatusTable'
Table of all alarms
acdAlarmStatusEntry row .1.3.6.1.4.1.22420.2.1.11.1
An alarm is an exceptional event that requires user notificaton.
Indexes
No indexes recorded
Column Syntax OID
Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes).
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22420.2.1.11.1.1
Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
AAA.BBB.CC and …
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22420.2.1.11.1.2
This is to indicate if the alarm is On or Off.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.22420.2.1.11.1.3
This is the time of the last change for this alarm. A value of zero
means that nothing happened to this alarm since the last reboot.
SNMPv2-TCDateAndTime
Type Constraints:
range: 8
range: 11
Description:
A date-time specification.

field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month …
.1.3.6.1.4.1.22420.2.1.11.1.4
This string is to add information why the alarm is reported.
OctetString .1.3.6.1.4.1.22420.2.1.11.1.5