A3COM-SWITCHING-SYSTEMS-FILTER-MIB
- Source file
A3COM-SWITCHING-SYSTEMS-FILTER-MIB- Last revised
- Not declared
Imported Objects
| RFC-1212 | OBJECT-TYPE (no object page) |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | DisplayString PhysAddress |
Objects (53)
Showing 53 of 53 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.43 | ||
.1.3.6.1.4.1.43.29 | ||
.1.3.6.1.4.1.43.29.4 | ||
.1.3.6.1.4.1.43.29.4.20 | ||
.1.3.6.1.4.1.43.29.4.20.1 | ||
| Integer32 | .1.3.6.1.4.1.43.29.4.20.1.1 | |
a3ComFilterAddressGroupCountmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.1.2 |
a3ComFilterAddressGroupTablemandatory | .1.3.6.1.4.1.43.29.4.20.1.3 | |
a3ComFilterAddressGroupEntrymandatory | .1.3.6.1.4.1.43.29.4.20.1.3.1 | |
a3ComFilterAddressGroupIdmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.1.3.1.1 |
a3ComFilterAddressGroupMaskIdmandatoryr/w | Integer32 | .1.3.6.1.4.1.43.29.4.20.1.3.1.2 |
a3ComFilterAddressGroupBridgeMaskmandatoryr/w | OctetString | .1.3.6.1.4.1.43.29.4.20.1.3.1.3 |
a3ComFilterAddressGroupNamemandatoryr/w | OctetString | .1.3.6.1.4.1.43.29.4.20.1.3.1.4 |
a3ComFilterAddressGroupStatusmandatoryr/w | RowStatus | .1.3.6.1.4.1.43.29.4.20.1.3.1.5 |
a3ComFilterAddressTablemandatory | .1.3.6.1.4.1.43.29.4.20.1.4 | |
a3ComFilterAddressEntrymandatory | .1.3.6.1.4.1.43.29.4.20.1.4.1 | |
a3ComFilterAddressIdmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.1.4.1.1 |
a3ComFilterAddressAddressmandatory | RFC1213-MIBPhysAddress | .1.3.6.1.4.1.43.29.4.20.1.4.1.2 |
a3ComFilterAddressStatusmandatoryr/w | RowStatus | .1.3.6.1.4.1.43.29.4.20.1.4.1.3 |
.1.3.6.1.4.1.43.29.4.20.2 | ||
| Integer32 | .1.3.6.1.4.1.43.29.4.20.2.1 | |
a3ComFilterPortGroupCountmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.2.2 |
a3ComFilterPortGroupTablemandatory | .1.3.6.1.4.1.43.29.4.20.2.3 | |
a3ComFilterPortGroupEntrymandatory | .1.3.6.1.4.1.43.29.4.20.2.3.1 | |
a3ComFilterPortGroupIdmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.2.3.1.1 |
a3ComFilterPortGroupMaskIdmandatoryr/w | Integer32 | .1.3.6.1.4.1.43.29.4.20.2.3.1.2 |
a3ComFilterPortGroupBridgeNumbermandatoryr/w | Integer32 | .1.3.6.1.4.1.43.29.4.20.2.3.1.3 |
a3ComFilterPortGroupNamemandatoryr/w | OctetString | .1.3.6.1.4.1.43.29.4.20.2.3.1.4 |
a3ComFilterPortGroupStatusmandatoryr/w | RowStatus | .1.3.6.1.4.1.43.29.4.20.2.3.1.5 |
a3ComFilterPortTablemandatory | .1.3.6.1.4.1.43.29.4.20.2.4 | |
a3ComFilterPortEntrymandatory | .1.3.6.1.4.1.43.29.4.20.2.4.1 | |
a3ComFilterPortIdmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.2.4.1.1 |
a3ComFilterPortTypemandatory | A3ComFilterPortType | .1.3.6.1.4.1.43.29.4.20.2.4.1.2 |
a3ComFilterPortPortmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.2.4.1.3 |
a3ComFilterPortStatusmandatoryr/w | RowStatus | .1.3.6.1.4.1.43.29.4.20.2.4.1.4 |
.1.3.6.1.4.1.43.29.4.20.3 | ||
a3ComBridgeFilterNextAvailableIndexmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.1 |
a3ComBridgeFilterCountmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.2 |
a3ComBridgeFilterTablemandatory | .1.3.6.1.4.1.43.29.4.20.3.3 | |
a3ComBridgeFilterEntrymandatory | .1.3.6.1.4.1.43.29.4.20.3.3.1 | |
a3ComBridgeFilterIdmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.3.1.1 |
a3ComBridgeFilterBridgeNumbermandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.3.1.2 |
a3ComBridgeFilterNamemandatory | OctetString | .1.3.6.1.4.1.43.29.4.20.3.3.1.3 |
a3ComBridgeFilterProgrammandatory | OctetString | .1.3.6.1.4.1.43.29.4.20.3.3.1.4 |
a3ComBridgeFilterStatusmandatoryr/w | RowStatus | .1.3.6.1.4.1.43.29.4.20.3.3.1.5 |
a3ComPortFilterTablemandatory | .1.3.6.1.4.1.43.29.4.20.3.4 | |
a3ComPortFilterEntrymandatory | .1.3.6.1.4.1.43.29.4.20.3.4.1 | |
a3ComPortFilterIdmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.4.1.1 |
a3ComPortFilterBridgeNumbermandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.4.1.2 |
a3ComPortFilterBridgePortTypemandatory | A3ComFilterPortType | .1.3.6.1.4.1.43.29.4.20.3.4.1.3 |
a3ComPortFilterBridgePortPortmandatory | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.4.1.4 |
a3ComPortFilterPktProcessPathmandatoryr/w | Integer32 | .1.3.6.1.4.1.43.29.4.20.3.4.1.5 |
a3ComPortFilterStatusmandatoryr/w | RowStatus | .1.3.6.1.4.1.43.29.4.20.3.4.1.6 |
Dependencies (6) 3 direct · 3 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- RFC-1212rfc
- RFC1155-SMIrfc
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- RFC1213-MIBrfc
- A3COM-SWITCHING-SYSTEMS-FILTER-MIBa3comselected
Type Definitions (2)
| Integer32 |
range: 1..5 |
|
| Enumeration |
active(1)notInService(2)notReady(3)createAndGo(4)createAndWait(5)destroy(6) |