v52IgLapvT203
ZhoneV52-MIB ·
.1.3.6.1.4.1.5504.4.3.2.2.1.5
Object
column
r/w
seconds Integer32
Maximum layer 2 idle time before connection
verification is necessary (T203).For all SAPS,
the value of T203 shall be user selectable within
the range of 10 to 300 seconds, inclusive, the
step size shall be 10 seconds, and the default
value shall be 10 seconds.
Currently, the value of this variable cannot be
changed and it will always be 10 seconds.
Context
- MIB
- ZhoneV52-MIB
- OID
.1.3.6.1.4.1.5504.4.3.2.2.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- v52InterfaceGroupLapvEntry
- Table
- v52InterfaceGroupLapvTable
- Siblings
- 4
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 160-160
range: 300-300
range: 290-290
range: 280-280
range: 270-270
range: 260-260
range: 250-250
range: 240-240
range: 230-230
range: 220-220
range: 210-210
range: 200-200
range: 190-190
range: 180-180
range: 170-170
range: 10-10
range: 150-150
range: 140-140
range: 130-130
range: 120-120
range: 110-110
range: 100-100
range: 90-90
range: 80-80
range: 70-70
range: 60-60
range: 50-50
range: 40-40
range: 30-30
range: 20-20
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| v52IgLapvMaxOutstandingFrames Maximum number of outstanding information frames
at layer 2
Range of valid values is 1-7. Default value is 7.
Currently, the value of this variab… | column | frames Integer32 | .1.3.6.1.4.1.5504.4.3.2.2.1.1 |
| v52IgLapvN200 The maximum number of retransmissions for a
frame allowed at layer 2, N200 shall be user
selectable within the range of 1 to 10, inclusive,
with a step size of 1 and a default v… | column | Integer32 | .1.3.6.1.4.1.5504.4.3.2.2.1.2 |
| v52IgLapvN201 The maximum number of octets in the information
field of an I frame, N201, shall be 260. (This
SAP is used for operations messages.) Valid
range is 0..260. Default is 260.
… | column | Integer32 | .1.3.6.1.4.1.5504.4.3.2.2.1.3 |
| v52IgLapvT200 Maximum layer 2 wait time for an acknowledgment
of a transmitted frame (T200) For all SAPs, the
value of T200 shall be user selectable within the
range of 100 ms to 1000 ms, inc… | column | milliseconds Integer32 | .1.3.6.1.4.1.5504.4.3.2.2.1.4 |