zyVlanStackPortMode
ZYXEL-VLAN-STACK-MIB ·
.1.3.6.1.4.1.890.1.15.3.89.1.2.1.1
Object
column
r/w
Enumeration
VLAN stacking mode of the port: Set Normal mode to have the switch ignore frames received(or transmitted) on this port with VLAN stacking tags. Set Access mode to have the switch add the SP TPID tag to all incoming frames received on this port. It is for ingress ports at the edge of the service provider's network. Set Tunnel mode (available for Gigabit ports only) for egress ports at the edge of the service provider's network. In order to support VLAN stacking on a port, the port must be able to allow frames of 1526 Bytes (1522 Bytes + 4 Bytes for the second tag) to pass through it.
Context
- MIB
- ZYXEL-VLAN-STACK-MIB
- OID
.1.3.6.1.4.1.890.1.15.3.89.1.2.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- zyxelVlanStackPortEntry
- Table
- zyxelVlanStackPortTable
- Siblings
- 3
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | normal |
2 | access |
3 | tunnel |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| zyVlanStackPortVid Stacking port VLAN ID is the service provider's VLAN ID (the outer VLAN tag).
Set the service provider ID (from 1 to 4094) for frames received on this port. | column | Integer32 | .1.3.6.1.4.1.890.1.15.3.89.1.2.1.2 |
| zyVlanStackPortPriority Set a priority level (from 0 to 7). This is the service provider's priority level that adds to the frames received on this port.
0 is the lowest priority level and 7 is the highes… | column | Enumeration | .1.3.6.1.4.1.890.1.15.3.89.1.2.1.3 |
| zyVlanStackTunnelPortTpid TPID is a standard Ethernet type code identifying the frame and indicates whether the frame carries IEEE 802.1Q tag information.
Set a four-digit hexadecimal number from 0000 to … | column | Integer32 | .1.3.6.1.4.1.890.1.15.3.89.1.2.1.4 |