zxAnVplsVfiCvTypeCapability
ZTE-AN-MPLS-L2VPN-MIB ·
.1.3.6.1.4.1.3902.1015.59.3.11.1.14
Object
column
ZxAnMplsVccvCvType
Connectivity Verification (CV) Types Capability, it indicates which CV types are supported.
Context
- MIB
- ZTE-AN-MPLS-L2VPN-MIB
- OID
.1.3.6.1.4.1.3902.1015.59.3.11.1.14- Type
- column
- Access
- readonly
- Status
- current
- Parent
- zxAnVplsVfiConfigEntry
- Table
- zxAnVplsVfiConfigTable
- Siblings
- 14
Syntax
ZxAnMplsVccvCvType
- Source
- ZxAnMplsVccvCvType
- Base type
Bits
Values & Constraints
Type Values
0 | icmpPing |
1 | lspPing |
2 | bfd |
3 | reserved1 |
4 | reserved2 |
5 | reserved3 |
6 | reserved4 |
7 | reserved5 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| zxAnVplsVfiName Virtual Forwarding Instance (VFI)is a virtual
Layer 2 forwarding entity that defines the VPLS domain
membership and resembles virtual switches on PE routers.
Each Virtual Forwardi… | column | OctetString | .1.3.6.1.4.1.3902.1015.59.3.11.1.1 |
| zxAnVplsVfiVcidType VCID Type, default value is dynamic. If VCID type configured here
is static, it indicates the VPLS domain is static too. | column | Enumeration | .1.3.6.1.4.1.3902.1015.59.3.11.1.10 |
| zxAnVplsVfiPwe3CWPreferred It indicates LDP entity prefers to use control word or not in PW. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3902.1015.59.3.11.1.11 |
| zxAnVplsVfiVccvEnable VCCV(Virtual Circuit Connectivity Verification) enable switch.
VCCV provides a control channel that is associated with
a pseudowire (PW), as well as the corresponding operations a… | column | Enumeration | .1.3.6.1.4.1.3902.1015.59.3.11.1.12 |
| zxAnVplsVfiCcTypeCapability Control Channel(CC) types Capability, it indicates which CC types
are supported. | column | ZxAnMplsVccvCcType | .1.3.6.1.4.1.3902.1015.59.3.11.1.13 |
| zxAnVplsVfiVcid This configures Virtual
Circuit id. When VPLS instances of two PE
routers belong to same VPLS region, it is required to
establish pseudo wire to continue the communication between… | column | Unsigned32 | .1.3.6.1.4.1.3902.1015.59.3.11.1.2 |
| zxAnVplsVfiPwType Two PEs need to negotiate pseudo wire type when they establish
PW.There are two types of PWs in VPLS which are ethernet and
ethernet-vlan.The former one supports transparent trans… | column | ZX-PWE3-MIBIANAPwTypeTC | .1.3.6.1.4.1.3902.1015.59.3.11.1.3 |
| zxAnVplsVfiRowStatus The rowstatus of zxAnVplsVfiConfigTable | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.3902.1015.59.3.11.1.30 |
| zxAnVplsVfiMaxMacLearningNum Max MAC learning number. | column | Integer32 | .1.3.6.1.4.1.3902.1015.59.3.11.1.4 |
| zxAnVplsVfiRemoteMacAgingTime Remote MAC aging time. | column | second Integer32 | .1.3.6.1.4.1.3902.1015.59.3.11.1.5 |
| zxAnVplsVfiLocalMacAgingTime Local MAC aging time. | column | second Integer32 | .1.3.6.1.4.1.3902.1015.59.3.11.1.6 |
| zxAnVplsVfiBCastRateLimit Broadcast rate limit. | column | kbps Integer32 | .1.3.6.1.4.1.3902.1015.59.3.11.1.7 |
| zxAnVplsVfiMCastRateLimit Multicast rate limit. | column | kbps Integer32 | .1.3.6.1.4.1.3902.1015.59.3.11.1.8 |
| zxAnVplsVfiUnknownUCastRateLimit Unknown unicast rate limit. | column | kbps Integer32 | .1.3.6.1.4.1.3902.1015.59.3.11.1.9 |