zxAnFanExAutoSwitchByCardInstall
ZTE-AN-EQUIP-MIB ·
.1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.2
Object
column
r/w
Enumeration
Enable/disable fan auto switch with card installation. If it is enabled,the fan under the card should be swiched to running status when the card is installed.Otherwise,the fan should be shutdown. NOTE: No recomanded to configure it in NMS.
Context
- MIB
- ZTE-AN-EQUIP-MIB
- OID
.1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- zxAnFanTrayExMgmtEntry
- Table
- zxAnFanTrayExMgmtTable
- Siblings
- 17
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | enable |
2 | disable |
Object Constraints
range: 8-8
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| zxAnFanExAlarmBeepEnable The control status of the fan alarm beep. | column | Enumeration | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.1 |
| zxAnFanExLowSpeedShiftTemp The temperature to activate the fan tray to shift to
the low speed level.
NOTE:
No recomanded to display it in NMS. | column | centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.10 |
| zxAnFanExStandardSpeedShiftTemp The temperature to activate the fan tray to shift to
the standard speed level.
NOTE:
No recomanded to display it in NMS. | column | centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.11 |
| zxAnFanExHighSpeedShiftTemp The temperature to activate the fan tray to shift to
the high speed level.
NOTE:
No recomanded to display it in NMS. | column | centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.12 |
| zxAnFanExSuperSpeedShiftTemp The temperature to activate the fan tray to shift to
the super speed level.
NOTE:
No recomanded to display it in NMS. | column | centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.13 |
| zxAnFanExLowSpeedPercentage The percentage of speed of the low speed level. | column | percent Integer32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.14 |
| zxAnFanExStandardSpeedPercentage The percentage of speed of the standard speed level. | column | percent Integer32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.15 |
| zxAnFanExHighSpeedPercentage The percentage of speed of the high speed level. | column | percent Integer32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.16 |
| zxAnFanExSuperSpeedPercentage The percentage of speed of the super speed level. | column | percent Integer32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.17 |
| zxAnFanExInvSn The serial number of fan board.It used by inventory management. | column | OctetString | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.18 |
| zxAnFanExHardwareVersion The hardware version of the fan tray | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.3 |
| zxAnFanExSoftwareVersion The software version of the fan tray | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.4 |
| zxAnFanExSpeedCtrlMode The speed control mode of the fan. | column | Enumeration | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.5 |
| zxAnFanExLowSpeed The speed value of the fan's low speed level.
The values for ZXDSL9800,9210 are 1500,2400,2700,3000,3400,3700,
4000,4400.
NOTE:
No recomanded to display it in NMS.
Different… | column | RPM SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.6 |
| zxAnFanExStandardSpeed The speed value of the fan's standard speed level.
The values for ZXDSL9800,9210 are 1500,2400,2700,3000,3400,3700,
4000,4400.
NOTE:
No recomanded to display it in NMS.
Diff… | column | RPM SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.7 |
| zxAnFanExHighSpeed The speed value of the fan's high speed level.
The values for ZXDSL9800,9210 are 1500,2400,2700,3000,3400,3700,
4000,4400.
NOTE:
No recomanded to display it in NMS.
Differen… | column | RPM SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.8 |
| zxAnFanExSuperSpeed The speed value of the fan's super speed level.
The values for ZXDSL9800,9210 are 1500,2400,2700,3000,3400,3700,
4000,4400.
NOTE:
No recomanded to display it in NMS.
Differe… | column | RPM SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3902.1015.2.1.7.2.1.1.9 |