s100FanOperationalStatus
ZHONE-SECHTOR100-MIB ·
.1.3.6.1.4.1.5504.2.4.1.1.1
Object
scalar
deprecated
Enumeration
This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'.
Context
- MIB
- ZHONE-SECHTOR100-MIB
- OID
.1.3.6.1.4.1.5504.2.4.1.1.1- Type
- scalar
- Access
- readonly
- Status
- deprecated
- Parent
- sechtor100Environment
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | operational |
2 | fanFailure |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| s100ThermoAUpperThreshold deprecated This variable specifies the upper threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
above this value, s100ThermoAOperationalStatus would be
'overUpper… | scalar | Integer32 | .1.3.6.1.4.1.5504.2.4.1.1.2 |
| s100ThermoBUpperThreshold deprecated This variable specifies the upper threshold for thermometer
B in degrees Celsius. When s100ThermoBTemperature is
above this value, s100ThermoBOperationalStatus would be
'overUpper… | scalar | Integer32 | .1.3.6.1.4.1.5504.2.4.1.1.3 |
| s10ThermoALowerThreshold deprecated This variable specifies the lower threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoAOperationalStatus would be
'belowLowe… | scalar | Integer32 | .1.3.6.1.4.1.5504.2.4.1.1.4 |
| s100ThermoBLowerThreshold deprecated This variable specifies the lower threshold for thermometer
B in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoBOperationalStatus would be
'belowLowe… | scalar | Integer32 | .1.3.6.1.4.1.5504.2.4.1.1.5 |
| s100ThermoATemperature deprecated The temperature in degrees Celsius read by the IC
thermometer sensor A on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer… | scalar | Integer32 | .1.3.6.1.4.1.5504.2.4.1.1.6 |
| s100ThermoBTemperature deprecated The temperature in degrees Celsius read by the IC
thermometer sensor B on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer… | scalar | Integer32 | .1.3.6.1.4.1.5504.2.4.1.1.7 |
| s100ThermoAOperationalStatus deprecated The operational status indicator for thermometer A.
Valid values are:
* withinOperationalRange - s100ThermoATemperature is within
its lower and upper threshold range.… | scalar | Enumeration | .1.3.6.1.4.1.5504.2.4.1.1.8 |
| s100ThermoBOperationalStatus deprecated The operational status indicator for thermometer B.
Valid values are:
* withinOperationalRange - s100ThermoBTemperature is within
its lower and upper threshold range.… | scalar | Enumeration | .1.3.6.1.4.1.5504.2.4.1.1.9 |