wtnLedStatus

ZHONE-GEN-WTN-MONITOR-MIB · .1.3.6.1.4.1.5504.3.9.1.1

Object

scalar Bits
Reflects current state of LEDs of indoor unit.
A bit value of 1 indicates the LED is ON.
A bit value of 0 indicates the LED of OFF.
          
Meaning of LEDs:
===========================================
diag -
  Upon power up the LED is turned on.  If the unit
successfully passes diagnostics, the LED is turned off.
  When operational, the LED is turned on when diagnostics
are performed or when the system detects an alarm.       
          
operational -
   Upon power up the LED is off.  When the system is
operating it is turned on.
   The actual LED is blinked when the ZMS link is down 
or during software download.
          
lineInterface -
   This LED is turned on when there are no wire-line alarms.
   For SkyZhone45 - this refers to the DS3 line.
   For SkyZhone155 - this refers to the fiber.
   For SkyZhone8e - this refers to the set of T1/E1 lines.
          
radio -
   This LED is turned on when there are no radio receive alarms. 
          
local- 
   This LED is turned on when there are not alarms present
on the Near End indoor or outdoor units.
          
remote -
   This LED is turned on when there are not alarms present
on the Far End indoor or outdoor units.

Context

MIB
ZHONE-GEN-WTN-MONITOR-MIB
OID
.1.3.6.1.4.1.5504.3.9.1.1
Type
scalar
Access
readonly
Status
current
Parent
wtnMonitor
Siblings
1

Syntax

Bits

Values & Constraints

Enumerated Values
0diag
1operational
2lineInterface
3radio
4local
5remote

Related Objects