wtWebGraphAirQualityAlarmFtpOption
WebGraph-OLD-Air-Quality-US-MIB ·
.1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.35
Object
column
mandatory
r/w
OctetString
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STORE
Bit 1 : APPEND
Bit 2-7: unused
Context
- MIB
- WebGraph-OLD-Air-Quality-US-MIB
- OID
.1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.35- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebGraphAirQualityAlarmEntry
- Table
- wtWebGraphAirQualityAlarmTable
- Siblings
- 39
Syntax
OctetString
Values & Constraints
Object Constraints
range: 4-4
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebGraphAirQualityAlarmTrigger mandatory Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Senso… | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.1 |
| wtWebGraphAirQualityAlarmMailText mandatory Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.10 |
| wtWebGraphAirQualityAlarmManagerIP mandatory Name or IP address of the SNMP Manager which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.11 |
| wtWebGraphAirQualityAlarmTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.12 |
| wtWebGraphAirQualityAlarmMailOptions mandatory Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.13 |
| wtWebGraphAirQualityAlarmTcpIpAddr mandatory Name or IP address of the TCP server which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.14 |
| wtWebGraphAirQualityAlarmTcpPort mandatory Port number of the TCP server which accepts the trap. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.15 |
| wtWebGraphAirQualityAlarmTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.16 |
| wtWebGraphAirQualityAlarmClearMailSubject mandatory Subject line for alarm clear mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.17 |
| wtWebGraphAirQualityAlarmClearMailText mandatory Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.18 |
| wtWebGraphAirQualityAlarmClearTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.19 |
| wtWebGraphAirQualityAlarmMin mandatory Minimum temperature in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.2 |
| wtWebGraphAirQualityAlarmClearTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.20 |
| wtWebGraphAirQualityAlarmDeltaTemp mandatory Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.21 |
| wtWebGraphAirQualityAlarmRHMin mandatory Minimum rel. Humidity in percent with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.22 |
| wtWebGraphAirQualityAlarmRHMax mandatory Maximum rel.Humidity in percent with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.23 |
| wtWebGraphAirQualityAlarmRHHysteresis mandatory Hysteresis of rel. Humidity in percent with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.24 |
| wtWebGraphAirQualityAlarmAHMin mandatory Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.25 |
| wtWebGraphAirQualityAlarmAHMax mandatory Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.26 |
| wtWebGraphAirQualityAlarmSyslogIpAddr mandatory IP address of the syslog server to which the Webio device should send syslog messages. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.27 |
| wtWebGraphAirQualityAlarmSyslogPort mandatory Port number of the syslog server to which the Webio device should send syslog messages. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.28 |
| wtWebGraphAirQualityAlarmSyslogText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.29 |
| wtWebGraphAirQualityAlarmMax mandatory Maximum temperature in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.3 |
| wtWebGraphAirQualityAlarmSyslogClearText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.30 |
| wtWebGraphAirQualityAlarmFtpDataPort mandatory Local data port: 1..65535 or AUTO: the next free port will be assigned. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.31 |
| wtWebGraphAirQualityAlarmFtpFileName mandatory Name of the file including path informations. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.32 |
| wtWebGraphAirQualityAlarmFtpText mandatory Message text to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.33 |
| wtWebGraphAirQualityAlarmFtpClearText mandatory Alarm clear message to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.34 |
| wtWebGraphAirQualityAlarmTimerCron mandatory This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are… | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.36 |
| wtWebGraphAirQualityAlarmVocMax mandatory Maximum VOC in ppm with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.37 |
| wtWebGraphAirQualityAlarmVocHysteresis mandatory Hysteresis of VOC in ppm with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.38 |
| wtWebGraphAirQualityAlarmName mandatory Alert name | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.39 |
| wtWebGraphAirQualityAlarmHysteresis mandatory Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.4 |
| wtWebGraphAirQualityAlarmActive mandatory Alert active
1 = ON
0 = OFF | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.40 |
| wtWebGraphAirQualityAlarmDelay mandatory Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.5 |
| wtWebGraphAirQualityAlarmInterval mandatory Send interval for alarm messages. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.6 |
| wtWebGraphAirQualityAlarmEnable mandatory Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.7 |
| wtWebGraphAirQualityAlarmEMailAddr mandatory E-Mail address for sending the alarm mail to. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.8 |
| wtWebGraphAirQualityAlarmMailSubject mandatory Subject line for alarm mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.9 |