wwpLeosLldpMessageTxHoldMultiplier

WWP-LEOS-LLDP-MIB · .1.3.6.1.4.1.6141.2.60.26.1.1.2

Object

scalar deprecated r/w Integer32
The time-to-live value expressed as a multiple of the
wwpLeosLldpMessageTxInterval object.  The actual time-to-live value
used in LLDP frames, transmitted on behalf of this LLDP agent,
can be expressed by the following formula: TTL = min(65535,
(wwpLeosLldpMessageTxInterval * wwpLeosLldpMessageTxHoldMultiplier)) For
example, if the value of wwpLeosLldpMessageTxInterval is '30', and
the value of wwpLeosLldpMessageTxHoldMultiplier is '4', then the
value '120' is encoded in the TTL field in the LLDP header.
          
The default value for wwpLeosLldpMessageTxHoldMultiplier object is 4.
          
If the agent is capable of storing non-volatile configuration,
then the value of this object must be restored after a
re-initialization of the management system.

Context

MIB
WWP-LEOS-LLDP-MIB
OID
.1.3.6.1.4.1.6141.2.60.26.1.1.2
Type