mdmIndex
WIPIPE-MIB ·
.1.3.6.1.4.1.20992.1.2.2.1.1
Object
column
mandatory
Integer32
A unique value, greater than zero, for each cellular modem. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
Context
- MIB
- WIPIPE-MIB
- OID
.1.3.6.1.4.1.20992.1.2.2.1.1- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- mdmEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-10