In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is down.
Reason: vmwNsxTDataCenterFailureReason.
          
Action required:
1. Invoke the NSX CLI command `get logical-routers`.
2. Switch to service-router vmwNsxTDataCenterSrId.
If the reason indicates Network or config error -
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the
BGP neighbor status.
If the reason indicates `Edge is not ready`, check why the Edge node is not in good state.
4. Invoke the NSX CLI command `get edge-cluster status` to check reason why Edge node might be down.
5. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
6. Check any Edge health related alarms to get more information.
Check /var/log/syslog to see if there are any errors related to BGP
connectivity.