vmwNsxTNodeAgentsHealthNodeAgentsDown
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.12.0.3
Object
notification
The agents running inside the Node VM appear to be down.
Action required:
For ESX:
1. If Vmk50 is missing, refer to this Knowledge Base article
https://kb.vmware.com/s/article/67432.
2. If Hyperbus 4094 is missing, restarting nsx-cfgagent or restarting the
container host VM may help.
3. If container host VIF is blocked, check the connection to the Controller
to make sure all configurations are sent down.
4. If nsx-cfg-agent has stopped, restart nsx-cfgagent.
For KVM:
1. If Hyperbus namespace is missing, restarting the nsx-opsagent may help
recreate the namespace.
2. If Hyperbus interface is missing inside the hyperbus namespace,
restarting the nsx-opsagent may help.
3. If nsx-agent has stopped, restart nsx-agent.
For Both ESX and KVM:
1. If the node-agent package is missing, check whether node-agent package
has been successfully installed in the container host vm.
2. If the interface for node-agent in container host vm is down, check the
eth1 interface status inside the container host vm.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.12.0.3- Type
- notification
- Status
- current
- Parent
- vmwNsxTNodeAgentsHealthFeature
- Siblings
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTNodeAgentsHealthNodeAgentsDownClear The agents inside the Node VM are running.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.12.0.4 |
| vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPU The agents running inside the Node VM appear to be down on DPU vmwNsxTDataCenterDPUId.
Action required:
1. If Vmk50 on DPU vmwNsxTDataCenterDPUId is missing, refer to t… | notification | - | .1.3.6.1.4.1.6876.120.1.0.12.0.5 |
| vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPUClear The agents inside the Node VM are running on DPU vmwNsxTDataCenterDPUId.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.12.0.6 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |