vmwNsxTNATSNATPortUsageOnGatewayIsHigh
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.46.0.1
Object
notification
SNAT ports usage on logical router vmwNsxTDataCenterEntityId for
SNAT IP vmwNsxTDataCenterSNATIPAddress has reached
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will
not be SNATed when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> connection state` by using the right interface
uuid and check various SNAT mappings for the SNAT IP vmwNsxTDataCenterSNATIPAddress.
Check traffic flows going through the gateway is not a denial-of-service
attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider adding more
SNAT IP addresses to distribute the load or
route new traffic to another Edge node.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.46.0.1- Type
- notification
- Status
- current
- Parent
- vmwNsxTNATFeature
- Siblings
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTNATSNATPortUsageOnGatewayIsHighClear SNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress
has reached below the high threshold value of vmwNsxTDataCenterSystemUsageT… | notification | - | .1.3.6.1.4.1.6876.120.1.0.46.0.2 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterSNATIPAddress This value is not expected to be empty. | scalar | VmwNsxTDataCenterSNATIPAddressType | .1.3.6.1.4.1.6876.120.1.1.128 |
| vmwNsxTDataCenterSystemUsageThreshold The configured threshold value for the CPU, memory, or disk usage
percentage of an NSX appliance. The value is an integer between 0 and
100. | scalar | VmwNsxTDataCenterSystemUsageThresholdType | .1.3.6.1.4.1.6876.120.1.1.34 |