vmwNsxTLoadBalancerDLBStatusDown
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.17.0.17
Object
notification
The distributed load balancer service vmwNsxTDataCenterEntityId is down.
Action required:
On ESXi host node, invoke the NSX CLI command `get load-balancer
<lb-uuid> status`.
If 'Conflict LSP' is reported, check whether this LSP is attached
to other load balancer service. Check whether this conflict is
acceptable.
If 'Not Ready LSP' is reported, check the status of this LSP by
invoking NSX CLI command `get logical-switch-port status`.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.17.0.17- Type
- notification
- Status
- current
- Parent
- vmwNsxTLoadBalancerFeature
- Siblings
- 17
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTLoadBalancerLBCPUVeryHigh The CPU usage of load balancer vmwNsxTDataCenterEntityId is very high. The threshold is
vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
If the load balancer CP… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.1 |
| vmwNsxTLoadBalancerPoolStatusDownClear The load balancer pool vmwNsxTDataCenterEntityId status is up
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.10 |
| vmwNsxTLoadBalancerVirtualServerStatusDown The load balancer virtual server vmwNsxTDataCenterEntityId is down.
Action required:
Consult the load balancer pool to determine its status and verify its
configuration… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.11 |
| vmwNsxTLoadBalancerVirtualServerStatusDownClear The load balancer virtual server vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.12 |
| vmwNsxTLoadBalancerLBStatusDegraded The load balancer service vmwNsxTDataCenterEntityId is degraded.
Action required:
For centralized load balancer:
Check the load balancer status on standby Edge node as … | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.15 |
| vmwNsxTLoadBalancerLBStatusDegradedClear The load balancer service vmwNsxTDataCenterEntityId is not degraded.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.16 |
| vmwNsxTLoadBalancerDLBStatusDownClear The distributed load balancer service vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.18 |
| vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory The load balancer configuration vmwNsxTDataCenterEntityId is not realized,
due to high memory usage on Edge node vmwNsxTDataCenterTransportNodeId.
Action required:
Pref… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.19 |
| vmwNsxTLoadBalancerLBCPUVeryHighClear The CPU usage of load balancer vmwNsxTDataCenterEntityId is low enough. The threshold is
vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this … | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.2 |
| vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear The load balancer configuration vmwNsxTDataCenterEntityId is realized on vmwNsxTDataCenterTransportNodeId.
Action required:
None, receipt of this notification indicates… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.20 |
| vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is high.
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
If multiple… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.3 |
| vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is low enough.
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None,… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.4 |
| vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh The usage of pool members in Edge node vmwNsxTDataCenterEntityId is very high.
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Deploy a new Ed… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.5 |
| vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear The usage of pool members in Edge node vmwNsxTDataCenterEntityId is low enough.
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt … | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.6 |
| vmwNsxTLoadBalancerLBStatusDown The centralized load balancer service vmwNsxTDataCenterEntityId is down.
Action required:
On active Edge node, check load balancer status by invoking the NSX CLI
comman… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.7 |
| vmwNsxTLoadBalancerLBStatusDownClear The centralized load balancer service vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.8 |
| vmwNsxTLoadBalancerPoolStatusDown The load balancer pool vmwNsxTDataCenterEntityId status is down.
Action required:
Consult the load balancer pool to determine which members are down by
invoking the NSX… | notification | - | .1.3.6.1.4.1.6876.120.1.0.17.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |