vmwNsxTLicensesLicenseExpired
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.5.0.1
Object
notification
The vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, has expired.
Action required:
Add a new, non-expired license using the NSX UI by navigating to
System | Licenses then click ADD and specify the key of the new
license. The expired license should be deleted by checking the
checkbox of the license, then click DELETE.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.5.0.1- Type
- notification
- Status
- current
- Parent
- vmwNsxTLicensesFeature
- Siblings
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTLicensesLicenseExpiredClear The expired vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
longer about to expire.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.5.0.2 |
| vmwNsxTLicensesLicenseIsAboutToExpire The vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, is about to expire.
Action required:
The license is about to expir… | notification | - | .1.3.6.1.4.1.6876.120.1.0.5.0.3 |
| vmwNsxTLicensesLicenseIsAboutToExpireClear The expiring vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
longer about to expire.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.5.0.4 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterLicenseEditionType The edition type of an NSX license. For example, the type for an NSX
evaluation license is 'NSX Data Center Evaluation'. | scalar | VmwNsxTDataCenterLicenseEditionTypeType | .1.3.6.1.4.1.6876.120.1.1.24 |
| vmwNsxTDataCenterDisplayedLicenseKey This value is not expected to be empty. | scalar | VmwNsxTDataCenterDisplayedLicenseKeyType | .1.3.6.1.4.1.6876.120.1.1.92 |