vmwNsxTIdentityFirewallErrorInDeltaSync
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.36.0.3
Object
notification
Errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
Action required:
1. Check if there are any connectivity to LDAP server lost alarms.
2. Find the error details in /var/log/syslog. Around the alarm trigger
time, search for text: Error happened when synchronize LDAP objects.
3. Check with AD administrator if there are any recent AD changes which
may cause the errors.
4. If the errors persist, collect the technical support bundle and
contact VMware technical support.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.36.0.3- Type
- notification
- Status
- current
- Parent
- vmwNsxTIdentityFirewallFeature
- Siblings
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTIdentityFirewallConnectivityToLDAPServerLost The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is lost.
Action required:
Check
1. The LDAP server is reachable from NSX nodes.
2. The LDAP server details a… | notification | - | .1.3.6.1.4.1.6876.120.1.0.36.0.1 |
| vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is restored.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.36.0.2 |
| vmwNsxTIdentityFirewallErrorInDeltaSyncClear No errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.36.0.4 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterDirectoryDomain This value is not expected to be empty. | scalar | VmwNsxTDataCenterDirectoryDomainType | .1.3.6.1.4.1.6876.120.1.1.81 |