vmwNsxTIPAMIPPoolUsageVeryHigh

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.38.0.3

Object

notification
IP pool usage of vmwNsxTDataCenterIntentPath is very high.
Creation of entity/service depends on IP being allocated from IP pool might fail.
          
Action required:
Review IP pool usage.
Release unused ip allocations from IP pool or create new IP pool and use it.
From NSX UI navigate to Networking | IP Address pools | IP Address pools tab.
Select IP pools and check Allocated IPs column, this will show IPs allocated from the
IP pool. If user see any IPs are not being used then those IPs can be released.
To release unused IP allocations, invoke the NSX API
DELETE /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations/<ip-allocation>

Context

MIB
VMWARE-NSX-MIB
OID
.1.3.6.1.4.1.6876.120.1.0.38.0.3