vmwNsxTIPAMIPPoolUsageVeryHigh
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.38.0.3
Object
notification
IP pool usage of vmwNsxTDataCenterIntentPath is very high.
Creation of entity/service depends on IP being allocated from IP pool might fail.
Action required:
Review IP pool usage.
Release unused ip allocations from IP pool or create new IP pool and use it.
From NSX UI navigate to Networking | IP Address pools | IP Address pools tab.
Select IP pools and check Allocated IPs column, this will show IPs allocated from the
IP pool. If user see any IPs are not being used then those IPs can be released.
To release unused IP allocations, invoke the NSX API
DELETE /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations/<ip-allocation>
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.38.0.3- Type
- notification
- Status
- current
- Parent
- vmwNsxTIPAMFeature
- Siblings
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTIPAMIPBlockUsageVeryHigh IP block usage of vmwNsxTDataCenterIntentPath is very high.
IP block nearing its total capacity, creation of subnet using IP block might fail.
Action required:
Review I… | notification | - | .1.3.6.1.4.1.6876.120.1.0.38.0.1 |
| vmwNsxTIPAMIPBlockUsageVeryHighClear IP block usage of vmwNsxTDataCenterIntentPath is below threshold level.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.38.0.2 |
| vmwNsxTIPAMIPPoolUsageVeryHighClear IP pool usage of vmwNsxTDataCenterIntentPath is normal now.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.38.0.4 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterIntentPath This value is not expected to be empty. | scalar | VmwNsxTDataCenterIntentPathType | .1.3.6.1.4.1.6876.120.1.1.94 |