vmwNsxTEndpointProtectionPartnerChannelDown
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.13.0.3
Object
notification
The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
is down.
Action required:
Refer to https://kb.vmware.com/s/article/85844 and make sure
that Partner SVM vmwNsxTDataCenterEntityId is re-connected to the host module.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.13.0.3- Type
- notification
- Status
- current
- Parent
- vmwNsxTEndpointProtectionFeature
- Siblings
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTEndpointProtectionEAMStatusDown ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is down.
Action required:
Start the ESX Agent Manager (EAM) service. SSH into vCenter and i… | notification | - | .1.3.6.1.4.1.6876.120.1.0.13.0.1 |
| vmwNsxTEndpointProtectionEAMStatusDownClear ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is either up
or compute manager vmwNsxTDataCenterEntityId has been removed.
Action required… | notification | - | .1.3.6.1.4.1.6876.120.1.0.13.0.2 |
| vmwNsxTEndpointProtectionPartnerChannelDownClear The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
is up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.13.0.4 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |