vmwNsxTEdgeHealthFailureDomainDown

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.2.0.53

Object

notification
All members of failure domain vmwNsxTDataCenterTransportNodeId are down.
          
Action required:
1. On the Edge node identified by vmwNsxTDataCenterTransportNodeId, check the connectivity
to the management and control planes by invoking the NSX CLI command
`get managers` and `get controllers`.
2. Invoke the NSX CLI command `get interface eth0` to check the management
interface status.
3. Invoke the CLI `get services` to check the core services status like
dataplane/local-controller/nestdb/router, etc.
4. Inspect the /var/log/syslog to find the suspecting error.
5. Reboot the Edge node.

Context

MIB
VMWARE-NSX-MIB
OID
.1.3.6.1.4.1.6876.120.1.0.2.0.53
Type
notification
Status
current
Parent
vmwNsxTEdgeHealthFeature
Siblings
43

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Notification Objects