vmwNsxTEdgeEdgeVmvSphereSettingsMismatch
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.45.0.5
Object
notification
The Edge node vmwNsxTDataCenterEntityId configuration on vSphere does not match the policy
intent configuration. The Edge node configuration visible to user on UI or API
is not same as what is realized. The realized Edge node changes made by user
outside of NSX Manager are shown in the details of this alarm and any edits
in UI or API will overwrite the realized configuration. Fields that differ for
the Edge node are listed in runtime data vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason
Action required:
Review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
Follow one of following actions to resolve alarm -
1. Accept intent or vSphere realized Edge node configuration for this Edge Transport Node
through Edge Transport Node resolver to resolve this alarm.
2. Resolve alarm by accepting the Edge node vSphere realized configuration using
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.45.0.5- Type
- notification
- Status
- current
- Parent
- vmwNsxTEdgeFeature
- Siblings
- 15
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged The Edge node vmwNsxTDataCenterEntityId settings and vSphere configuration are changed and does not
match the policy intent configuration. The Edge node configuration visible to u… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.1 |
| vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenterClear Edge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter.
Action required:
None, receipt of this not… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.10 |
| vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenter The VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node
vmwNsxTDataCenterEntityId vSphere placement parameters i… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.11 |
| vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenterClear Edge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter.
Action required:
None, receipt of this not… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.12 |
| vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeploy Failed to power off and delete the Edge node vmwNsxTDataCenterEntityId VM with moref id vmwNsxTDataCenterVMMorefId
in vCenter during Redeploy operation. A new Edge VM with moref i… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.13 |
| vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeployClear Edge node vmwNsxTDataCenterEntityId with stale VM moref id vmwNsxTDataCenterVMMorefId is not found
anymore in both NSX inventory and vCenter. New deployed VM with moref id vmwNsxT… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.14 |
| vmwNsxTEdgeEdgeHardwareVersionMismatch The Edge node vmwNsxTDataCenterTransportNodeName in Edge cluster vmwNsxTDataCenterEdgeClusterName has a hardware version vmwNsxTDataCenterEdgeTNHwVersion,
which is less than the h… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.15 |
| vmwNsxTEdgeEdgeHardwareVersionMismatchClear The Edge node vmwNsxTDataCenterTransportNodeName hardware version mismatch is resolved now.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.16 |
| vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear Edge node vmwNsxTDataCenterEntityId node settings and vSphere settings are consistent with policy intent now.
Action required:
None, receipt of this notification indica… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.2 |
| vmwNsxTEdgeEdgeNodeSettingsMismatch The Edge node vmwNsxTDataCenterEntityId settings configuration does not match the policy
intent configuration. The Edge node configuration visible to user on
UI or API is not same… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.3 |
| vmwNsxTEdgeEdgeNodeSettingsMismatchClear Edge node vmwNsxTDataCenterEntityId node settings are consistent with policy intent now.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.4 |
| vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear Edge node vmwNsxTDataCenterEntityId VM vSphere settings are consistent with policy intent now.
Action required:
None, receipt of this notification indicates event clear… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.6 |
| vmwNsxTEdgeEdgevSphereLocationMismatch The Edge node vmwNsxTDataCenterEntityId has been moved using vMotion. The Edge node vmwNsxTDataCenterEntityId, the configuration
on vSphere does not match the policy intent config… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.7 |
| vmwNsxTEdgeEdgevSphereLocationMismatchClear Edge node vmwNsxTDataCenterEntityId node vSphere settings are consistent with policy intent now.
Action required:
None, receipt of this notification indicates event cle… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.8 |
| vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenter The VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node
vmwNsxTDataCenterEntityId vSphere placement parameters i… | notification | - | .1.3.6.1.4.1.6876.120.1.0.45.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason This value is not expected to be empty. | scalar | VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType | .1.3.6.1.4.1.6876.120.1.1.124 |