vmwNsxTDNSForwarderDownClear
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.30.0.4
Object
notification
DNS forwarder vmwNsxTDataCenterEntityId is running again.
Action required:
None, receipt of this notification indicates event cleared.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.30.0.4- Type
- notification
- Status
- current
- Parent
- vmwNsxTDNSFeature
- Siblings
- 5
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDNSForwarderDisabled DNS forwarder vmwNsxTDataCenterEntityId is disabled.
Action required:
1. Invoke the NSX CLI command `get dns-forwarders status` to verify
if the DNS forwarder is in the… | notification | - | .1.3.6.1.4.1.6876.120.1.0.30.0.1 |
| vmwNsxTDNSForwarderDisabledClear DNS forwarder vmwNsxTDataCenterEntityId is enabled.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.30.0.2 |
| vmwNsxTDNSForwarderDown DNS forwarder vmwNsxTDataCenterEntityId is not running. This is impacting the
identified DNS Forwarder that is currently enabled.
Action required:
1. Invoke the NSX CLI… | notification | - | .1.3.6.1.4.1.6876.120.1.0.30.0.3 |
| vmwNsxTDNSForwarderUpstreamServerTimeout DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) did not receive a timely response
from upstream server vmwNsxTDataCenterDNSUpstreamIP. Compute instance connectiv… | notification | - | .1.3.6.1.4.1.6876.120.1.0.30.0.5 |
| vmwNsxTDNSForwarderUpstreamServerTimeoutClear DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) upstream server vmwNsxTDataCenterDNSUpstreamIP
is normal.
Action required:
None, receipt of this notif… | notification | - | .1.3.6.1.4.1.6876.120.1.0.30.0.6 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |