vmwNsxTCommunicationUnreachableCollectorOnDPU

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.35.0.33

Object

notification
The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can not be reached via existing vmknic(s)(stack vmwNsxTDataCenterStackAlias)
on any DVS on DPU vmwNsxTDataCenterDPUId.
          
Action required:
To make the collector reachable for given vertical on the DVS, user has to make sure there
is(are) vmknic(s) with expected stack vmwNsxTDataCenterStackAlias created and configured with approriate IPv4(6)
addresses, and the network connection to vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP is also fine. So user has
to do the checking on DPU vmwNsxTDataCenterDPUId, and perform required configuration to make sure the condition
is met. Finally if `vmkping vmwNsxTDataCenterCollectorIP -S vmwNsxTDataCenterStackAlias`  with SSH to DPU via ESXi enabled succeeds,
this indicates the problem is gone.