vmwNsxMSsoDisconnected

VMWARE-NSX-MANAGER-MIB · .1.3.6.1.4.1.6876.90.1.2.2.0.12

Object

notification
Whenever there is disconnection with SSO lookup service.
Action required: Please check the configuration for possible disconnection
reasons like Invalid Credentials, Time sync issues, Network connectivity
problems etc. Navigate to Appliance management Web UI in browser
(https://<nsx-manager-host>/) traverse to Manage vCenter Registration tab
and verify the configuration for SSO Lookupservice.
Frequency of traps: Once per disconnect event, default frequency to check
SSO connection state is 1 hour.