vmwNsxMFabricConnEamFailed

VMWARE-NSX-MANAGER-MIB · .1.3.6.1.4.1.6876.90.1.2.7.0.19

Object

notification
NSX Manager relies on the ESX Agent Manager service in VC for
deploying/monitoring NSX vibs on ESX. The connection to this EAM service
has gone down. This could be due to EAM service or VC restart/stop or an
issue in the EAM service.
Action required: In the NSX UI, traverse to Manage, then NSX Management
Service. Verify that the status of VC connection on this page is Green.
Use the VC IP to verify that EAM is UP by visiting https://<vc ip>/eam/mob.
Frequency of traps: Once per switch from success to failed EAM connection

Context

MIB
VMWARE-NSX-MANAGER-MIB
OID
.1.3.6.1.4.1.6876.90.1.2.7.0.19
Type
notification
Status
current
Parent
vmwNsxMFabricPrefix
Siblings
23

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Notification Objects