vmwNsxMEdgeHaSwitchOverSelf

VMWARE-NSX-MANAGER-MIB · .1.3.6.1.4.1.6876.90.1.2.4.0.40

Object

notification
A notification generated when High Availability is disabled for NSX Edge.
The primary NSX Edge VM has its state transitioned from ACTIVE to SELF.
High Availability (HA) ensures that NSX Edge services are always available,
by deploying an additional Edge VM for failover. The primary NSX Edge VM is
the ACTIVE node and the secondary VM is the STANDBY node. Whenever the
ACTIVE VM is unreachable on account of VM powered off or network
connectivity issues, the STANDBY VM takes over the ACTIVE vm's role.
In the event NSX Edge High Availability is disabled, the STANDBY VM is
deleted and the ACTIVE VM continues to function with its ACTIVE state
transitioned to SELF.