voltageOutOfRange
VES1724-58V-TRAPS-MIB ·
.1.3.6.1.4.1.890.1.5.12.49.19.3.2
Object
notification
Send a message to notify the manager that the voltage of the system is out of range. The variable in the binding list is the current voltage in volt of the system.
Context
- MIB
- VES1724-58V-TRAPS-MIB
- OID
.1.3.6.1.4.1.890.1.5.12.49.19.3.2- Type
- notification
- Status
- current
- Parent
- equipment
- Siblings
- 29
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwMonitorFail Hardware monitor diagnosis is failed. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.1 |
| extAlarmInput1Release The trap signifies that the external alarm input 1 of MSC card
is released. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.10 |
| extAlarmInput2Trigger The trap signifies that the external alarm input 2 of MSC card
is triggered. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.11 |
| extAlarmInput2Release The trap signifies that the external alarm input 2 of MSC card
is released. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.12 |
| extAlarmInput3Trigger The trap signifies that the external alarm input 3 of MSC card
is triggered. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.13 |
| extAlarmInput3Release The trap signifies that the external alarm input 3 of MSC card
is released. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.14 |
| extAlarmInput4Trigger The trap signifies that the external alarm input 4 of MSC card
is triggered. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.15 |
| extAlarmInput4Release The trap signifies that the external alarm input 4 of MSC card
is released. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.16 |
| voltageNormal Send a message to notify the manager that the out-of-range condition is over.
The variable in the binding list is the current voltage in volt
of the system. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.3 |
| acDown The trap signifies AC power is down | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.38 |
| acDownClear The trap signifies AC power down is cleared | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.39 |
| temperatureOutOfRange Send a message to notify the manager that the system is out of range.
The variable in the binding list is the current temperature in Celsius
of the system. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.4 |
| battTempSensorAbsent The trap signifies the battery temperature sensor is absent | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.43 |
| battTempSensorAbsentClear The trap signifies battTempSensorAbsent alarm is cleared | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.44 |
| batteryTempOutofRange The trap signifies battery temperature not between normal threshold | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.45 |
| batteryTempNormal The trap signifies battery temperature abnormal is cleared | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.46 |
| dcCriticIssue The trap signifies AC power is down and battery voltage under the threshold | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.49 |
| temperatureNormal Send a message to notify the manager that the out-of-range condition is over.
The variable in the binding list is the current temperature in Celsius
of the system. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.5 |
| dcCriticClear The trap signifies DC critic alarm is cleared | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.50 |
| dcLowIssue The trap signifies AC power is down and battery voltage under the threshold | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.51 |
| dcLowClear The trap signifies DC Low alarm is cleared | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.52 |
| dcErrorIssue The trap signifies the battery is too low to be charged | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.53 |
| dcErrorClear The trap signifies dc error alarm is cleared | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.54 |
| dcFailIssue The trap signifies the battery is absent | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.55 |
| dcFailClear The trap signifies dc fail alarm is cleared | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.56 |
| fanRpmOutOfRange Send a message to notify the manager that the rpm of the fan is out of range.
The variable in the binding list is the current rpm of the fan. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.6 |
| fanRpmNormal Send a message to notify the manager that the out-of-range condition of the fan is over.
The variable in the binding list is the current rpm of the fan. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.7 |
| hwRtcFail Send a message to notify the manager that the hardware RTC is failed. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.8 |
| extAlarmInput1Trigger The trap signifies that the external alarm input 1 of MSC card
is triggered. | notification | - | .1.3.6.1.4.1.890.1.5.12.49.19.3.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sysCoaIssuedLoad CPU analyzed utilization when CPU overload alarm is issued. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.12.49.19.1.6 |
| VES1724-58V-MIBcoaConfIssueThreshold CPU overload alarm issue threshold.
CPU overload alarm issue threshold should be higher than CPU overload alarm clear threshold. | scalar | Unsigned32 | .1.3.6.1.4.1.890.1.5.12.49.20.1 |
| VES1724-58V-MIBcoaConfAnalyticMethod Analytic method of cpu overload alarm.
continuous: if all samples are above <issue-threshold> , issue a CPU overload alarm. If all samples are below <clear-threshold>, clear the C… | scalar | Enumeration | .1.3.6.1.4.1.890.1.5.12.49.20.4 |