geLinkStatus
VES1724-58V-MIB ·
.1.3.6.1.4.1.890.1.5.12.49.4.1.1.4
Object
column
Enumeration
displays GE speed and duplex mode inactive(0) - inactive linkdown(1) - link down halfx10(2) - 10Base-T half duplex mode (Copper) fullx10(3) - 10Base-T full duplex mode (Copper) halfx100(4) - 100Base-TX half duplex mode (Copper) fullx100(5) - 100Base-TX full duplex mode (Copper) fullx1000(6) - 1000Base-T full duplex mode (Copper) fiberx1000(7) - 1000Base-X full duplex mode (SFP)
Context
- MIB
- VES1724-58V-MIB
- OID
.1.3.6.1.4.1.890.1.5.12.49.4.1.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- geConfEntry
- Table
- geConfTable
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | inactive |
1 | linkdown |
2 | halfx10 |
3 | fullx10 |
4 | halfx100 |
5 | fullx100 |
6 | fullx1000 |
7 | fiberx1000 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| geConfName Sets a name for the port(s). | column | OctetString | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.1 |
| geUtilTxIssueLvl2Threshold GE utilization alarm issue level two threshold for tx direction, the threshold value of level two should be
higher than level one. | column | Unsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.10 |
| geUtilRxIssueLvl1Threshold GE utilization alarm level one threshold for rx direction, the threshold value of level two should be
higher than level one. | column | Unsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.11 |
| geUtilRxIssueLvl2Threshold GE utilization alarm level two threshold for rx direction, the threshold value of level two should be
higher than level one. | column | Unsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.12 |
| geUtilSampleSeconds Sample seconds of GE utilization alarm | column | Unsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.13 |
| geConfSpeedDuplex Configures GE speed and duplex mode
auto(1) - auto negotiation (both Copper and SFP PHY)
halfx10(2) - 10Base-T half duplex mode (Copper)
fullx10(3) - 10Base-T full duplex mode (Co… | column | Enumeration | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.2 |
| geConfAlarmProf Sets ENET alarm profile for the port(s). | column | OctetString | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.3 |
| geUtilTxCurrentPercent GE current utilization in 0.01 percentage(100 = 1.00%). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.5 |
| geUtilTxCurrentSpeed GE current utilization in kbps. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.6 |
| geUtilRxCurrentPercent GE current utilization in 0.01 percentage(100 = 1.00%). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.7 |
| geUtilRxCurrentSpeed GE current utilization in kbps. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.8 |
| geUtilTxIssueLvl1Threshold GE utilization alarm issue level one threshold for tx direction, the threshold value of level two should be
higher than level one. | column | Unsigned32 | .1.3.6.1.4.1.890.1.5.12.49.4.1.1.9 |