terminalTraps
V320-MIB ·
.1.3.6.1.4.1.39003.2.22
Object
node
No description available.
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| terminalLinkQuality A measure for quality of the microwave link.
Green: good signal level to withstand heavy rain
Yellow: sufficient signal level but no margin
Red: insufficient signal level, link no… | scalar | Enumeration | .1.3.6.1.4.1.39003.2.1 |
| terminalReceivePower Receive signal level in dBm | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.39003.2.10 |
| terminalTemperature Temperature within the unit in degree Celsius | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.39003.2.11 |
| terminalLockDetector Lock detection signal level | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.39003.2.12 |
| terminalLinkQualityImproved Indicates a positive change of the received microwave signal
and the quality change from red to green or from red to yellow. | scalar | Enumeration | .1.3.6.1.4.1.39003.2.13 |
| terminalLinkQualityReduced Indicates a negative change of the received microwave signal
and the quality change from red to green or from red to yellow. | scalar | Enumeration | .1.3.6.1.4.1.39003.2.14 |
| terminalFirmwareversion Installed Firmware Version. | scalar | OctetString | .1.3.6.1.4.1.39003.2.21 |
| terminalAuxVoltage Actual Voltage at Auxilary Port | scalar | OctetString | .1.3.6.1.4.1.39003.2.25 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| terminalLinkQualityImprovedTrap A trap indicating that the microwave signal quality did increase. | notification | - | .1.3.6.1.4.1.39003.2.22.1 |
| terminalLinkQualityReducedTrap A trap indicating that the microwave signal quality did decrease. | notification | - | .1.3.6.1.4.1.39003.2.22.2 |
| terminalTemperatureHighTrap A trap indicating that the temperature within the unit
is over or below 70 degree Celsius. | notification | - | .1.3.6.1.4.1.39003.2.22.3 |
| terminalTemperatureLowTrap A trap indicating that the temperature within the unit
is over or below -40 degree Celsius. | notification | - | .1.3.6.1.4.1.39003.2.22.4 |