upsExtMeasMinHumidity
UPS2-MIB ·
.1.3.6.1.4.1.52.4.1.1.10.8.1.1.8
Object
column
mandatory
r/w
Enumeration
The lower humidity limit at which an alarm will be sent.
Context
- MIB
- UPS2-MIB
- OID
.1.3.6.1.4.1.52.4.1.1.10.8.1.1.8- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- upsExtMeasEntry
- Table
- upsExtMeasTable
- Siblings
- 15
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | tenPercent |
2 | twentyPercent |
3 | thirtyPercent |
4 | fortyPercent |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsExtMeasFwVersion mandatory The External Measurement Unit's firmware version letter. | column | OctetString | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.1 |
| upsExtMeasContact2AlarmControl mandatory The alarm enable state for the External Measurement Unit's
contact input channel #2. If enabled, an alarm will be
sent when contact input channel #2 has changed to abnormal
state. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.10 |
| upsExtMeasContact3AlarmControl mandatory The alarm enable state for the External Measurement Unit's
contact input channel #3. If enabled, an alarm will be
sent when contact input channel #3 has changed to abnormal
state. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.11 |
| upsExtMeasContact4AlarmControl mandatory The alarm enable state for the External Measurement Unit's
contact input channel #4. If enabled, an alarm will be
sent when contact input channel #4 has changed to abnormal
state. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.12 |
| upsExtMeasMaxTempAlarmControl mandatory The alarm enable state for the External Measurement Unit's
upper temperature limit. If enabled, an alarm will be
sent when the ambient temperature rises above the upper
temperatu… | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.13 |
| upsExtMeasMinTempAlarmControl mandatory The alarm enable state for the External Measurement Unit's
lower temperature limit. If enabled, an alarm will be
sent when the ambient temperature falls below the lower
temperatu… | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.14 |
| upsExtMeasMaxHumidityAlarmControl mandatory The alarm enable state for the External Measurement Unit's
upper humidity limit. If enabled, an alarm will be sent
when the ambient relative humidity rises above the upper
humidi… | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.15 |
| upsExtMeasMinHumidityAlarmControl mandatory The alarm enable state for the External Measurement Unit's
lower humidity limit. If enabled, an alarm will be sent
when the ambient relative humidity falls below the lower
humidi… | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.16 |
| upsExtMeasTemp mandatory The local ambient temperature in degrees Fahrenheit as measured
by the External Measurement Unit. The value of this object
is the actual temperature * 100 (that is, to determine … | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.2 |
| upsExtMeasHumidity mandatory The local ambient relative humidity in percent as measured
by the External Measurement Unit. The value of this object
is the actual humidity * 10 (that is, to determine the
actua… | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.3 |
| upsExtMeasAlarmStatus mandatory This object contains 8 bits of information about the current
alarm status of the External Measurement Unit. The bits are
encoded as follows:
BIT 7: 1=Upper temper… | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.4 |
| upsExtMeasMaxTemp mandatory The upper temperature limit at which an alarm will be sent. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.5 |
| upsExtMeasMinTemp mandatory The lower temperature limit at which an alarm will be sent. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.6 |
| upsExtMeasMaxHumidity mandatory The upper humidity limit at which an alarm will be sent. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.7 |
| upsExtMeasContact1AlarmControl mandatory The alarm enable state for the External Measurement Unit's
contact input channel #1. If enabled, an alarm will be
sent when contact input channel #1 has changed to abnormal
state. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.8.1.1.9 |