upsBatteryTestResult
UPS2-MIB ·
.1.3.6.1.4.1.52.4.1.1.10.3.1.1.4
Object
column
mandatory
Enumeration
The result of the last battery test performed.
Context
- MIB
- UPS2-MIB
- OID
.1.3.6.1.4.1.52.4.1.1.10.3.1.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- upsBatteryEntry
- Table
- upsBatteryTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | batteryOK |
2 | batteryBad |
3 | noRecentTest |
4 | invalidTestDueToOverload |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsBatteryCapacity mandatory The UPS's remaining battery capacity expressed as a percent
of the fully charged condition. The value of this object is
the actual percentage * 10 (that is, to determine the actu… | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.1 |
| upsBatteryVoltage mandatory The UPS's present battery voltage. The value of this object
is the actual voltage * 100 (that is, to determine the actual
voltage, divide the value of this object by 100). | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.2 |
| upsBatteryTest mandatory This object may be written to initiate testing of the UPS's
battery packs. Reading this object will always return a 0. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.3 |
| upsRunTimeCalibration mandatory This object may be written to initiate or terminate the test
used to calibrate the returned run time value. This test
will only run if battery capacity is 100%. Results of this … | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.5 |
| upsEstimatedRunTimeRemaining mandatory The UPS's estimated remaining run time in minutes. The UPS
may be queried when operating in the on-line, bypass, or
on-battery modes of operation. The run time estimate is
based… | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.6 |
| upsTransferCause mandatory The reason for the most recent transfer to on-battery
operation. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.7 |
| upsBatteryTestTime mandatory The frequency of execution of the UPS's automatic battery
test. The test may be run immediately upon startup, upon
startup and every 7 days thereafter, upon startup and every
14 … | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.8 |
| upsLowBatteryWarning mandatory The interval between activation of the UPS's low battery
alarm warnings and shutdown of the UPS. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.10.3.1.1.9 |