upsAlarmBypassBad
UPS-MIB ·
.1.3.6.1.2.1.33.1.6.3.10
Object
node
The Bypass is out of tolerance.
Context
- MIB
- UPS-MIB
- OID
.1.3.6.1.2.1.33.1.6.3.10- Type
- node
- Status
- current
- Parent
- upsWellKnownAlarms
- Siblings
- 23
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmBatteryBad One or more batteries have been determined to require
replacement. | node | - | .1.3.6.1.2.1.33.1.6.3.1 |
| upsAlarmOutputOffAsRequested The UPS has shutdown as requested, i.e., the output
is off. | node | - | .1.3.6.1.2.1.33.1.6.3.11 |
| upsAlarmUpsOffAsRequested The entire UPS has shutdown as commanded. | node | - | .1.3.6.1.2.1.33.1.6.3.12 |
| upsAlarmChargerFailed An uncorrected problem has been detected within the
UPS charger subsystem. | node | - | .1.3.6.1.2.1.33.1.6.3.13 |
| upsAlarmUpsOutputOff The output of the UPS is in the off state. | node | - | .1.3.6.1.2.1.33.1.6.3.14 |
| upsAlarmUpsSystemOff The UPS system is in the off state. | node | - | .1.3.6.1.2.1.33.1.6.3.15 |
| upsAlarmFanFailure The failure of one or more fans in the UPS has been
detected. | node | - | .1.3.6.1.2.1.33.1.6.3.16 |
| upsAlarmFuseFailure The failure of one or more fuses has been detected. | node | - | .1.3.6.1.2.1.33.1.6.3.17 |
| upsAlarmGeneralFault A general fault in the UPS has been detected. | node | - | .1.3.6.1.2.1.33.1.6.3.18 |
| upsAlarmDiagnosticTestFailed The result of the last diagnostic test indicates a
failure. | node | - | .1.3.6.1.2.1.33.1.6.3.19 |
| upsAlarmOnBattery The UPS is drawing power from the batteries. | node | - | .1.3.6.1.2.1.33.1.6.3.2 |
| upsAlarmCommunicationsLost A problem has been encountered in the communications
between the agent and the UPS. | node | - | .1.3.6.1.2.1.33.1.6.3.20 |
| upsAlarmAwaitingPower The UPS output is off and the UPS is awaiting the
return of input power. | node | - | .1.3.6.1.2.1.33.1.6.3.21 |
| upsAlarmShutdownPending A upsShutdownAfterDelay countdown is underway. | node | - | .1.3.6.1.2.1.33.1.6.3.22 |
| upsAlarmShutdownImminent The UPS will turn off power to the load in less than
5 seconds; this may be either a timed shutdown or a
low battery shutdown. | node | - | .1.3.6.1.2.1.33.1.6.3.23 |
| upsAlarmTestInProgress A test is in progress, as initiated and indicated by
the Test Group. Tests initiated via other
implementation-specific mechanisms can indicate the
presence of the testing in the … | node | - | .1.3.6.1.2.1.33.1.6.3.24 |
| upsAlarmLowBattery The remaining battery run-time is less than or equal
to upsConfigLowBattTime. | node | - | .1.3.6.1.2.1.33.1.6.3.3 |
| upsAlarmDepletedBattery The UPS will be unable to sustain the present load
when and if the utility power is lost. | node | - | .1.3.6.1.2.1.33.1.6.3.4 |
| upsAlarmTempBad A temperature is out of tolerance. | node | - | .1.3.6.1.2.1.33.1.6.3.5 |
| upsAlarmInputBad An input condition is out of tolerance. | node | - | .1.3.6.1.2.1.33.1.6.3.6 |
| upsAlarmOutputBad An output condition (other than OutputOverload) is
out of tolerance. | node | - | .1.3.6.1.2.1.33.1.6.3.7 |
| upsAlarmOutputOverload The output load exceeds the UPS output capacity. | node | - | .1.3.6.1.2.1.33.1.6.3.8 |
| upsAlarmOnBypass The Bypass is presently engaged on the UPS. | node | - | .1.3.6.1.2.1.33.1.6.3.9 |