mal-ore-compr1
UNCDZ-MIB ·
.1.3.6.1.4.1.9839.2.1.1.42
Object
Service Alarm: Compressor 1 hour counter threshold
Context
- MIB
- UNCDZ-MIB
- OID
.1.3.6.1.4.1.9839.2.1.1.42- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- N/A
- Parent
- digitalObjects
- Siblings
- 64
Syntax
N/A SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vent-on System On (Fan) | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.1 |
| on-deum Dehumidification | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.10 |
| power Humidification | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.11 |
| mal-access Tampering Alarm | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.12 |
| mal-ata Alarm: Room High Temperature | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.13 |
| mal-bta Alarm: Room Low Temperature | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.14 |
| mal-aua Alarm: Room High Humidity | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.15 |
| mal-bua Alarm: Room Low Humidity | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.16 |
| mal-eap Alarm: Room High/Low Temp./Humid.(Ext. Devices) | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.17 |
| mal-filter Alarm: Clogged Filter | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.18 |
| mal-flood Alarm: Water Leakage Detected | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.19 |
| compressore1 Compressor 1 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.2 |
| mal-flux Alarm: Loss of Air Flow | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.20 |
| mal-heater Alarm: Heater Overheating | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.21 |
| mal-hp1 Alarm: High Pressure 1 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.22 |
| mal-hp2 Alarm: High Pressure 2 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.23 |
| mal-lp1 Alarm: Low Pressure 1 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.24 |
| mal-lp2 Alarm: Low Pressure 2 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.25 |
| mal-phase Alarm: Wrong phase sequence | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.26 |
| mal-smoke Alarm: SMOKE-FIRE DETECTED | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.27 |
| mal-lan Alarm: Interrupted LAN | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.28 |
| mal-hcurr Humidifier Alarm: High Current | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.29 |
| compressore2 Compressor 2 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.3 |
| mal-nopower Humidifier Alarm: Power Loss | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.30 |
| mal-nowater Humidifier Alarm: Water Loss | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.31 |
| mal-cw-dh Alarm: Chilled Water Temp. too High for Dehumidification | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.32 |
| mal-tc-cw Alarm: CW Valve Failure or Water Flow too Low | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.33 |
| mal-wflow Alarm: Loss of Water flow | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.34 |
| mal-wht Alarm: High chilled water temp. | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.35 |
| mal-sonda-ta Alarm: Room air Sensor Failure/Disconnected | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.36 |
| mal-sonda-tac Alarm: Hot water Sensor Failure/Disconnected | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.37 |
| mal-sonda-tc Alarm: Condensing water Sensor Failure/Disconnect. | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.38 |
| mal-sonda-te Alarm: Outdoor temp. Sensor Failure/Disconnected | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.39 |
| compressore3 Compressor 3 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.4 |
| mal-sonda-tm Alarm: Delivery temp. Sensor Failure/Disconnected | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.40 |
| mal-sonda-ua Alarm: Rel. Humidity Sensor Failure/Disconnected | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.41 |
| mal-ore-compr2 Service Alarm: Compressor 2 hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.43 |
| mal-ore-compr3 Service Alarm: Compressor 3 hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.44 |
| mal-ore-compr4 Service Alarm: Compressor 4 hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.45 |
| mal-ore-filtro Service Alarm: Air Filter hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.46 |
| mal-ore-risc1 Service Alarm: Heater 1 hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.47 |
| mal-ore-risc2 Service Alarm: Heater 2 hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.48 |
| mal-ore-umid Service Alarm: Humidifier hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.49 |
| compressore4 Compressor 4 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.5 |
| mal-ore-unit Service Alarm: Unit hour counter threshold | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.50 |
| glb-al General Alarm | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.51 |
| or-al-2lev 2nd Level Alarm | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.52 |
| range-t-ext Outdoor Temp. Sensor Fitted | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.53 |
| range-t-circ Closed Circuit (or Chilled) Water Temperature Sensor Fitted | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.54 |
| range-t-man Delivery Temp. Sensor Fitted | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.55 |
| range-t-ac Hot water temp. Sensor Fitted | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.56 |
| umid-al Humidifier general alarm | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.57 |
| range-u-amb Relative Humidity Sensor Fitted | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.58 |
| out-h1 Heating 1 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.6 |
| k-syson Unit Remote Switch-On/Off Control | scalar | N/A Integer32 | .1.3.6.1.4.1.9839.2.1.1.60 |
| xs-res-al Buzzer and Alarm Remote Reset Control | scalar | N/A Integer32 | .1.3.6.1.4.1.9839.2.1.1.61 |
| sleep-mode Set Back Mode (Sleep Mode) | scalar | N/A Integer32 | .1.3.6.1.4.1.9839.2.1.1.63 |
| test-sm Set Back mode: Cyclical Start of Fan | scalar | N/A Integer32 | .1.3.6.1.4.1.9839.2.1.1.64 |
| ab-mediath Usage of T+ H Values: Local (0) / Mean (1) | scalar | N/A Integer32 | .1.3.6.1.4.1.9839.2.1.1.65 |
| ustdby1-2 No. Of Stand-by Units: one (0) / two (1) | scalar | N/A Integer32 | .1.3.6.1.4.1.9839.2.1.1.66 |
| emerg Unit in Emergency operation | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.67 |
| out-h2 Heating 2 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.7 |
| out-h3 Heating 3 | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.8 |
| gas-caldo-on Hot Gas Coil | scalar | N/A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9839.2.1.1.9 |