tnPowerMgmtIngressPortPerChannelInUseTargetOffset
TROPIC-POWERMGMT-MIB ·
.1.3.6.1.4.1.7483.2.1.6.2.1.22.1.3
Object
column
r/w
mB Integer32
The target power offset relative to common target
power currently in use.
Current configurable range: -300 to 300.
Context
- MIB
- TROPIC-POWERMGMT-MIB
- OID
.1.3.6.1.4.1.7483.2.1.6.2.1.22.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Units
- mB
- Parent
- tnPowerMgmtIngressPortPerChannelEntry
- Table
- tnPowerMgmtIngressPortPerChannelTable
- Siblings
- 4
Syntax
mB Integer32
Values & Constraints
Object Constraints
range: -300-300
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tnPowerMgmtIngressPortPerChannelSystemTargetOffset The SCOT system derived target power offset relative
to common target power.
Current configurable range: -300 to 300. | column | mB Integer32 | .1.3.6.1.4.1.7483.2.1.6.2.1.22.1.1 |
| tnPowerMgmtIngressPortPerChannelUserTargetOffset The user configured target power offset relative to
common target power. -9900 means not configured by
user.
Current configurable range: -9900, -300 to 300. | column | mB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7483.2.1.6.2.1.22.1.2 |
| tnPowerMgmtIngressPortPerChannelTargetAbsolute The SCOT target power in absolute power.
Current range: -9900 to 1100. | column | mBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7483.2.1.6.2.1.22.1.4 |
| tnPowerMgmtIngressPortPerChannelApplicability Values include:
notApplicable - No Och XCo configured for this ITU