tnOpsPortConfigSwitchingThreshold

TROPIC-OPTICALPORT-MIB · .1.3.6.1.4.1.7483.2.2.4.3.4.212.1.1

Object

column r/w mBm SNMPv2-SMIInteger32
If the power drops below this threshold, a
protection switch will be executed.  This is
accessible from ports 2 and 3 (working or
protected) exclusively.  This command applies
to ports A and B only.  Default is -3000 for
OCH protection, -2800 for OMS protection, and
-3000 for OLP protection.
              
Current configurable ranges and defaults:
              
OLP (OPSA)     :   (-3150..500), -2800
OCH/OMSP (OPSB):   (-3000..500), -1000
OMSP (OPSA)    :   (-3000..1700),-1000.

Context

MIB
TROPIC-OPTICALPORT-MIB
OID
.1.3.6.1.4.1.7483.2.2.4.3.4.212.1.1
Type
column
Access
readwrite
Status
current
Units
mBm
Parent
tnOpsPortConfigEntry
Table
tnOpsPortConfigTable
Siblings
8

Syntax

mBm SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects