tnPerPtpObjectAlarmCategory
TROPIC-LOG-MIB ·
.1.3.6.1.4.1.7483.2.1.3.2.4.12.1.5
Object
The category. The valid configurable values are:
criticalAlarms(1)
majorAlarms(2)
minorAlarms(3)
notAlarmed(7)
none(8)
notReported(10)
warningAlarms(12)
Setting the category to be equal to the default
category is the same as setting it to none. The
category is returned as none, as a result.
Context
- MIB
- TROPIC-LOG-MIB
- OID
.1.3.6.1.4.1.7483.2.1.3.2.4.12.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tnPerPtpObjectAlarmCategoryConfigEntry
- Table
- tnPerPtpObjectAlarmCategoryConfigTable
- Siblings
- 6
Values & Constraints
Type Values
1 | criticalAlarms |
2 | majorAlarms |
3 | minorAlarms |
4 | stateChanges |
5 | uiActions |
6 | generalEvents |
7 | notAlarmed |
8 | none |
9 | unknown |
10 | notReported |
11 | security |
12 | warningAlarms |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tnPtpAlarmCategoryObjectId The format for a PTP object instance is
shelf/slot//ptpclock/ptpport/direction:
shelf: 1 byte;
slot: 1 byte;
ptpclock: 3 bits;
ptpport: 13 bits).
- ptpport equa… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7483.2.1.3.2.4.12.1.1 |
| tnPtpAlarmCategoryDirection The direction to which the new category will be
applied. | column | AluWdmAlarmCategoryDirection | .1.3.6.1.4.1.7483.2.1.3.2.4.12.1.2 |
| tnPtpAlarmCategoryEntityType The AID type. | column | TROPIC-TCTnEntityType | .1.3.6.1.4.1.7483.2.1.3.2.4.12.1.3 |
| tnPtpAlarmCategoryCondition The condition. | column | TROPIC-TCTnCondition | .1.3.6.1.4.1.7483.2.1.3.2.4.12.1.4 |
| tnPerPtpObjectAlarmEntityTypeCategory The entity type category. | column | TROPIC-TCTnTrapCategory | .1.3.6.1.4.1.7483.2.1.3.2.4.12.1.6 |
| tnPerPtpObjectAlarmDefaultCategory The default category. | column | TROPIC-TCTnTrapCategory | .1.3.6.1.4.1.7483.2.1.3.2.4.12.1.7 |