upsWellKnownAlarms
TRIPPUPS1-MIB ·
.1.3.6.1.4.1.850.1.1.7
Object
node
No description available.
Context
- MIB
- TRIPPUPS1-MIB
- OID
.1.3.6.1.4.1.850.1.1.7- Type
- node
- Parent
- ups
- Siblings
- 8
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsIdent | node | - | .1.3.6.1.4.1.850.1.1.1 |
| upsConfig | node | - | .1.3.6.1.4.1.850.1.1.10 |
| upsBattery | node | - | .1.3.6.1.4.1.850.1.1.2 |
| upsInput | node | - | .1.3.6.1.4.1.850.1.1.3 |
| upsOutput | node | - | .1.3.6.1.4.1.850.1.1.4 |
| upsAlarm | node | - | .1.3.6.1.4.1.850.1.1.6 |
| upsTest | node | - | .1.3.6.1.4.1.850.1.1.8 |
| upsControl | node | - | .1.3.6.1.4.1.850.1.1.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmBatteryBad mandatory One or more batteries have been determined to require
replacement. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.1 |
| upsAlarmCommunicationsLost mandatory A problem has been encountered in the
communications between the agent and the UPS. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.10 |
| upsAlarmShutdownPending mandatory A upsShutdownAfterDelay countdown is underway. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.11 |
| upsAlarmShutdownImminent mandatory A upsShutdownAfterDelay countdown is underway. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.12 |
| upsAlarmTestInProgress mandatory A upsShutdownAfterDelay countdown is underway. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.13 |
| upsAlarmOnBattery mandatory The UPS is drawing power from the batteries. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.2 |
| upsAlarmLowBattery mandatory The remaining battery run-time is less than or equal
to upsConfigMinutesRemaining. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.3 |
| upsAlarmDepletedBattery mandatory The UPS will be unable to sustain the present load
when and if the utility power is lost. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.4 |
| upsAlarmTempBad mandatory A temperature is out of tolerance. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.5 |
| upsAlarmOutputOverload mandatory The output load exceeds the UPS output capacity. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.6 |
| upsAlarmOutputOffAsRequested mandatory The UPS has shutdown as commanded, i.e., the output is off. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.7 |
| upsAlarmUpsOutputOff mandatory The UPS is in the off state. | scalar | Integer32 | .1.3.6.1.4.1.850.1.1.7.8 |
| upsAlarmDiagnosticTestFailed mandatory The result of the last diagnostic test indicates a