tlpPduInputLowTransferVoltageLowerBound
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.5
Object
The lower boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.5- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.1 Volts
- Parent
- tlpPduInputEntry
- Table
- tlpPduInputTable
- Siblings
- 9
Syntax
0.1 Volts SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpPduInputNominalVoltage The nominal value of the input line voltage. This value may not
be supported on all models. If not supported, this value will return
ERROR_NO_SUCH_NAME. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.1 |
| tlpPduInputCurrentLimit The capacity of each phase conductor in the pdu limited by the AC input
cord or any other potential limiting factors unique to a given unit. | column | Amps SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.10 |
| tlpPduInputNominalVoltagePhaseToPhase The nominal value of the input line voltage as measured from
phase to phase. This value may not be supported on all models.
If not supported, this value will always return zero. | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.2 |
| tlpPduInputNominalVoltagePhaseToNeutral The nominal value of the input line voltage as measured from
phase to neutral. This value may not be supported on all models.
If not supported, this value will always return zero. | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.3 |
| tlpPduInputLowTransferVoltage The minimum line voltage allowed before the unit disconnects the
AC input connection. This value may not be writable on all models.
If not writable, the value will be rejected and… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.4 |
| tlpPduInputLowTransferVoltageUpperBound The upper boundary value of tlpPduInputLowTransferVoltage as dictated
by the hardware of the unit. | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.6 |
| tlpPduInputHighTransferVoltage The maximum line voltage allowed before the unit disconnects the
AC input connection. This value may not be writable on all models.
If not writable, the value will be rejected and… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.7 |
| tlpPduInputHighTransferVoltageLowerBound The lower boundary value of tlpPduInputHighTransferVoltage as dictated
by the hardware of the unit. | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.8 |
| tlpPduInputHighTransferVoltageUpperBound The upper boundary value of tlpPduInputHighTransferVoltage as dictated
by the hardware of the unit. | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.9 |