tlpNotificationsAtsSource2NotAvailable
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.4.2.6.2
Object
notification
This notification is sent when input on source two is not available. For atss with the designation of primary and secondary, this notification denotes input on the secondary source is not available.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.4.2.6.2- Type
- notification
- Status
- current
- Parent
- tlpNotificationsAts
- Siblings
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpNotificationsAtsSource1NotAvailable This notification is sent when input on source one is not available.
For atss with the designation of primary and secondary, this
notification denotes input on the primary source … | notification | - | .1.3.6.1.4.1.850.1.4.2.6.1 |
| tlpNotificationsAtsSource2VoltageDrop This notification is sent when the voltage on source 2 drops below a
usable state. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.10 |
| tlpNotificationsAtsTimedReturnToSource1 This notification is sent when the active input source returns to
source 1 from source 2 after a delay time expires. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.11 |
| tlpNotificationsAtsTimedReturnToSource2 This notification is sent when the active input source returns to
source 2 from source 1 after a delay time expires. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.12 |
| tlpNotificationsAtsTransferToSource1 This notification is sent when the active input source transfers
from source 2 to source 1. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.13 |
| tlpNotificationsAtsTransferToSource2 This notification is sent when the active input source transfers
from source 1 to source 2. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.14 |
| tlpNotificationsAtsLockdownToSource1 This notification is sent upon a transfer circuit fault causing the
device to be locked on source 1. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.3 |
| tlpNotificationsAtsLockdownToSource2 This notification is sent upon a transfer circuit fault causing the
device to be locked on source 2. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.4 |
| tlpNotificationsAtsSource1Available This notification is sent when source 1 is available and ready for
use. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.5 |
| tlpNotificationsAtsSource2Available This notification is sent when source 2 is available and ready for
use. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.6 |
| tlpNotificationsAtsSource1Brownout This notification is sent when a brownout condition occurred on source 1. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.7 |
| tlpNotificationsAtsSource2Brownout This notification is sent when a brownout condition occurred on source 2. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.8 |
| tlpNotificationsAtsSource1VoltageDrop This notification is sent when the voltage on source 1 drops below a
usable state. | notification | - | .1.3.6.1.4.1.850.1.4.2.6.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| SNMPv2-MIBsysUpTime The time (in hundredths of a second) since the
network management portion of the system was last
re-initialized. | scalar | SNMPv2-SMITimeTicks | .1.3.6.1.2.1.1.3 |
| tlpNotifyEventTableRef This value references the OID of a table object applicable to the event
condition. This, in conjunction with the table row as defined by
tlpAlarmTableRowRef, specifies the object/… | scalar | ObjectIdentifier | .1.3.6.1.4.1.850.1.4.3.1 |
| tlpNotifyEventTableRowRef This value is used in conjunction with tlpNotifyEventTableRef to define the
object associated with this event condition. See the description of
tlpNotifyEventTableRef for more inf… | scalar | ObjectIdentifier | .1.3.6.1.4.1.850.1.4.3.2 |