tlpCoolingRemoteDegC
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.7
Object
The external remote temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.7- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.1 degrees Celsius
- Parent
- tlpCoolingTemperatureCelsiusEntry
- Table
- tlpCoolingTemperatureCelsiusTable
- Siblings
- 7
Syntax
0.1 degrees Celsius SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpCoolingAmbientDegC The ambient temperature in tenths degrees Celsius. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.1 |
| tlpCoolingSupplyAirDegC The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.2 |
| tlpCoolingReturnAirDegC The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.3 |
| tlpCoolingCondenserInletDegC The temperature of the air entering the condenser in tenths degrees Celsius. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.4 |
| tlpCoolingEvaporatorDegC The temperature of the evaporator surface in tenths degrees Celsius. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.5 |
| tlpCoolingSuctionDegC The temperature of the low pressure refrigerant line in tenths degrees Celsius. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.6 |
| tlpCoolingCondenserOutletDegC The temperature of the air leaving the condenser in tenths degrees Celsius. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.8 |