tlCoolingUnitCurrent
TRIPPLITE-12X ·
.1.3.6.1.4.1.850.103.1.2.11
Object
scalar
SNMPv2-SMIInteger32
The the total current draw of the unit in tenths of Arms.
Context
- MIB
- TRIPPLITE-12X
- OID
.1.3.6.1.4.1.850.103.1.2.11- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- tlCoolingStatus
- Siblings
- 15
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlCoolingCondOutletTemp The condenser outlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.1 |
| tlCoolingEEVPercentage The opening percentage of the EEV. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.10 |
| tlCoolingFanCurrent Thethe current draw of the Evaporator and Condenser fans in tents of Arms. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.12 |
| tlCoolingCompCurrent The operating current of the compressor in Arms. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.13 |
| tlCoolingReturnAirTemp The return air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.14 |
| tlCoolingSuctionTemp The temperature of the compressor suction line in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.15 |
| tlCoolingSupplyAirTemp The supply air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.16 |
| tlCoolingCondInletTemp The condenser inlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.2 |
| tlCoolingRefrigerantTemp The temperature of the refrigerant in the suction line. This is displayed in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.3 |
| tlCoolingEvapSurfaceTemp The surface temperature of the evaporator in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.4 |
| tlCoolingSuctionPressure The pressure of the compressor suction line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.5 |
| tlCoolingDischargePressure The pressure of the compressor discharge line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.6 |
| tlCoolingEvapFanSpeed The current speed of the evaporator fan. | scalar | Enumeration | .1.3.6.1.4.1.850.103.1.2.7 |
| tlCoolingCondFanSpeed The current speed of the condenser fan. | scalar | Enumeration | .1.3.6.1.4.1.850.103.1.2.8 |
| tlCoolingCompFrequency The operating frequency of the compressor in tenths of Arms. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.103.1.2.9 |